LBC-H-R-SCL-ICP User Manual
Link Bridge
TM
HBaseT HDMI Receiver with Inline Control Processor
Broadata Technical Support, [email protected]
23
Flow Control
: Select
On
to enable flow control and
Off
to disable flow
control. Flow control is available only on Channel 1. If flow control is
enabled, Channel 2 is no longer available.
End of Line Pattern
: Select CR or CR+LF for end of line termination.
Local Unit Digital IO Options
The 3 pull down menus in this panel are used to configure the Digital IO
settings. Digital IOs are inputs by default and show up as triggers in the
Configure Auto Actions
page.
Digital IO Channel
: Select channel
1
or
2
.
Digital IO Direction:
Select channel as a digital
Input
or
Output
.
If the Digital IO Direction is set to
Input
, there is an option for
Pullup
Resistor
.
Pullup Resistor
: Select
Enable
or
Disable
pull-up resistor.
If the Digital IO Direction is set to
Output
, there is an option for
Digital
Output Mode
.
Digital Output Mode
: Select
TTL
for a 5V compatible TTL type output
or
Open Collector
for an open collector type output. An open collector
type output can be used to implement a contact closure type output.
For example, if a digital output is set to
Open Collector
, setting the
Digital Output State to
1 (High)
will emulate a switch closure to ground
.
Setting the Digital Output State to 0 (Low) will emulate a switch being
open. The Open Collector output also has an option for a Pullup Resistor.
Remote Unit
This panel enables the connection with the remote unit and selects the
remote unit type. This panel is not available if the Local unit type is
Standalone ICP
.
Remote Connection
: Select
Enable
to enable the connection with the
remote unit. Select
Disable
to disable the connection with the remote
unit and enable the RS-232 pass-through channel. RS-232 channel 3
(remote) will not be available.