LBC-H-R-SCL-ICP User Manual
Link Bridge
TM
HBaseT Receiver with Inline Control Processor
Broadata Technical Support, (800) 214-0222
22
Local Unit
The first two lines in this panel show the Local unit type and software
version. Below that is the address setup and status for the Network
Keypad. The last 2 pull down menus are for selecting the virtual keypad
size and enabling Auto Action Triggers.
Network Keypad Address
: Enter the IP address of the network keypad
(LB-KP8E or LB-KP16E) if one is present in the system. Use the
BCI
Product Configuration
program to discover the network keypad’s IP
address.
Network Keypad Status
: Shows type of network keypad connected
to ICP.
Virtual Keypad Size
: Select
8 keys
or
16 keys
. 8 keys option: maximum
of 10 actions per key. 16 keys option: maximum of 5 actions per key.
Auto Action Triggers
: Select
Enable
to enable the auto action triggers
defined in the
Configure Auto Action
page. Select
Disable
to disable
all auto action triggers.
Local Unit RS-232 Options
This panel is used to configure the local RS-232 channels.
Channel:
Select channel 1, 2 or 3. Note: Channel 3 is only available
on LBC-ICP and EAD/SCL-ICP units.
Channel 1/2
: RS-232 control channels.
Channel 3
: RS-232 control channel or pass-through channel. Channel
3 defaults as a control channel. Set Remote Connection (Remote Unit
panel) to Disable in order to configure Channel 3 as a pass-through
channel. Channel 3 (Remote) is the pass-through channel on the remote
unit.
Baud Rate
: Select a baud rate from 9600 to 115200 baud.