BroadAccess CAG40D-MIN Installation Guide
P/N 760-000718 Rev A
March 2006
Page 9
3.1.2. Parts
Required
Table 2 lists the parts required for installation of a single CAG40D-MIN:
Table 2.
KIT-19”-E Installation Kit
Item
Part Description
CAT No.
Quantity
1
Front panel fixings
HH23/55468
26
2
Nut, hex, S.S. M6
HN06/N0000
26
3 Nut,
floating
M6
HN06/NF006
26
4
Screw, pan-phil. M6x16
HS06/N6P15
26
5
Washer, plastic, M6x14
HW06/P0006
26
6
ADP-CAG-M adapter panel for 19” rack
(optional)
722Y73-901 1
3.1.3. Tools
Required
•
Phillips screwdriver
•
Crimping tool
•
Digital voltmeter (DVM)
•
Hexagonal head ¼ ” screwdriver
3.1.4. Installation
Procedure
Note:
Numbers in brackets refer to the item column of Table 2.
1
. Attach ADP-CAG-M adapter panel (item 6) to CAG40D-MIN left wall side
using screws and washers (items 4, 5), as shown in Figure 1.
2
. Prepare the screws for installation by inserting them in the plastic washers as
follows:
For racks with square holes: use screws (item 4) and washers (item 5)
For racks with round holes: use screws (item 4) and washers (item 1)
3
. Install floating nuts (item 3 for racks with square holes; item 2 for racks with
round holes) behind the rack front rail for each of the four holes (two on each
side).
4
. Place the CAG40D-MIN at the required height.
5
. For each of the four holes in the front of the CAG40D-MIN (two on each side),
insert the assembled screw and washer from the front of the CAG40D-MIN,
and secure with the floating nuts.
Содержание CAG40D-MIN