91834 Rev. C
3
B.
1
4
4
2
3
60 Series Installation
1
Cartridge Installation
A.
Turn off water supplies.
Remove cover (1),
bonnet nut (2), test cap (3) and plasterguard (4).
If screen (5) is in place, remove before installing
cartridge.
Plasterguard may be discarded.
1
2
3
4
Rotate the cartridge (1) so the word “UP” (2)
appears on the top. Insert cartridge into valve
body as shown. Make sure the cartridge tubes
and O-rings (3) are properly seated in holes at
the base of the body. Ensure the keys on the
body are fully engaged with the slots in the
body (4).
For back to back or reverse installations
(hot on right and cold on left): Rotate cartridge
(1) so the word “UP” (2) appears on the bottom.
Install the cartridge making sure that the keys are
fully engaged with the slots in the brass body (see
step B). Slide bonnet nut (3) over the cartridge
and thread onto the body. Hand tighten securely.
Slide bonnet nut (1) over the cartridge and
thread onto the body. Hand tighten securely.
C.
1
5
Back to back Installation
Normal Installation
(changes not required)
Reverse
Installation
Cold
Hot
1
3
2
Содержание MultiChoice VETTIS T60088
Страница 8: ...91834 Rev C 8 ...
Страница 16: ...91834 Rev C 8 ...
Страница 24: ...91834 Rev C 8 Delta Faucet Company Product Service 55 E 111th Street Indianapolis IN 46280 ...