92658 Rev. A
Potential scald or thermal shock injury could result due to cross flow if outlet at
the shower is blocked or restricted (e.g., pause control on showerhead). Be sure
to point showerhead away from you when re-starting flow or install inlet check
valves on both supply lines to prevent possible injury.
5
Faucet leaks from tub spout/showerhead:
SHUT OFF WATER SUPPLIES.
R
eplace seats and springs–Repair
Kit RP4993. Check condition of lower O-rings
and replace if necessary RP14414. See
Helpful Hints 1, 2, & 3.
If leak persists:
SHUT OFF WATER SUPPLIES.
Replace valve cartridge RP46074.
See Helpful Hints 1, 2, 3 & 5.
Unable to maintain constant
water temperature:
Replace valve cartridge RP46074 or follow
instructions in Helpful Hints 1, 2, 4 & 5.
Helpful Hints:
1. Before removing valve cartridge assembly
for any maintenance, be sure to note the
position of the rotational limit stop on the cap.
The valve cartridge assembly must always be
put back in the same position. BE SAFE! After
you have finished the installation, turn on
valve to make sure COLD WATER FLOWS
FIRST.
2. To remove valve cartridge from body, shut
off water supplies and remove handle and
bonnet nut. Do not pry the valve cartridge
out of the body with a screwdriver. Place
handle on stem and rotate counterclockwise
approximately 1/4 turn after the stop has
been contacted. Lift valve cartridge out of
body.
3. To remove seats and springs, remove
valve cartridge. Separate cap assembly
from the housing assembly by rotating
the cap assembly counterclockwise 90
o
(degrees). Separate cap and housing
assemblies. Remove seats and springs and
replace. Place the largest diameter of the
spring into the seat pocket first and then
press the tapered end of the seal over the
spring. Reassemble valve cartridge and
replace in body following instructions given
in 1 above.
4. If the water in your area has lime,
rust, sand or other contaminants in it,
your pressure balance valve will require
periodic inspection. The frequency of the
inspection will depend on the amount of
contaminants in the water. To inspect valve
cartridge remove it and follow the steps in
note 1 above. Turn the valve to the full mix
position and shake the cartridge vigorously.
If there is a rattling sound, the unit is
functional and can be reinstalled following
instructions given in note 1 above. If
there is no rattle, replace valve cartridge
RP46074.
5. Push disc until fully seated. See page 5
for more details.
T75P Series Maintenance
8
Содержание MultiChoice T75P Series
Страница 10: ...92658 Rev A ...
Страница 20: ...92658 Rev A ...
Страница 32: ...92658 Rev A Brizo Kitchen Bath Company Product Service 55 E 111th Street Indianapolis IN 46280 ...