Commissioning
B115 06/16 Rev.2
ZIRKON D060 D – D140 D
14
7
Commissioning
7.1
Setup
INFORMATION!
All illustrated numbered components refer to the positions in the illustration of
figure 4 on page 12.
During assembly and setup of the machine care should be taken to ensure that
the cooling air inlet (position 1) and the cooling air outlet (position 7) are at
least 10 cm away from adjacent walls.
For de-assembly of the filter box cover, cover hood and exhaust screen, 30 cm
space must be available for maintenance work.
Assembly of the ZIRKON can be undertaken on a stable and secure surface
without the need for fixed footings.
For assembly on an lower construction we recommend a fixture having elastic
rubber shock absorbers.
Vibration of machines of the ZIRKON construction series is minimal.
INFORMATION!
For assembly at levels greater than 1000 metres above sea-level, reduced
output is noticeable.
In this case, we advise prior advice from the manufacturer.
7.2
Installation
WARNING!
Mortal danger from electrical shocks!
Non-professional handling of electrical components can lead to life-threatening
electric shocks, if undertaken with insufficient experience.
Electrical installations should only be undertaken by qualified personnel
Fused security for the construction should be carried out via the main
junction box.
TAKE CARE!
Accident avoidance directions should be observed:
For all activities involving the assembly and start-up procedures, the accident
avoidance regulations “Compressors“ VBG 16 must be observed!