Setting Sensor Identification on an NC-6 when
used as a Slave
(refer Table 4. example)
•
Determine which NC-6 Controller will be the Master and
which one will be the Slave
•
Mount the proposed NC-6 Slave onto the backing plate of
the NC-6 that has power supplied directly from the heater
control board
•
Change the NC-6 Slave identification number to
“3”
by
accessing Installer Parameters (see 6.3, p.14)
•
Fit the NC-6 Slave to its designated zone backing plate only
after the unit ID has been changed
•
Mount the Master Controller onto its backing plate – this will
not require a unit ID change
•
Once an NC-6 has been designated a ‘Slave’, Installer
Parameters will no longer be accessible from this NC-6.
The Master Controller must then be used to access the
installer parameters
6.2.2 ZonePlus with all NC-6 Controllers
All NC-6 controllers that are used in place of NT-1 sensors
must have their sensor ID altered so that it operates as a slave.
Important Notes:
•
Only the NC-6 Controller backing plates should be wired
and installed
Power up the system in the following sequence:
•
516 Network Module (if applicable)
•
N-PM1 Power Module (if applicable)
•
Heater
•
Cooling System (if applicable)
Table 5:
4-Zone System Using All NC-6 Controllers
(example)
Zone ID
Sensor
Type
Function
Unit ID
Factory
Setting
Unit ID
System
Setting
Zone A
NC-6
Master
“n01”
“n01”
Zone B
NC-6
Slave
“n01”
“n02”
Zone C
NC-6
Slave
“n01”
“n03”
Zone D
NC-6
Slave
“n01”
“n04”
Always set and record all parameters in the Appendix.
Setting Sensor Identification on an NC-6 when
all are used as Slaves
(refer Table 5. example)
•
Determine which NC-6 Controller will be the Master and
which ones will be Slaves
•
Mount one of the proposed NC-6 Slaves onto the backing
plate of the NC-6 that has power supplied directly from the
heater control board
•
Change the NC-6 ID number to
“2”
by accessing Installer
Parameters (see 6.3, p.14)
•
Repeat for the remaining two Slaves and set unit ID to
“3”
and
“4”
respectively
•
Fit the NC-6 Slaves to their designated zone backing plates
only after all unit ID have been changed
•
Mount the Master Controller onto its backing plate – this will
not require a unit ID change
•
Once an NC-6 has been designated a ‘Slave’, Installer
Parameters will no longer be accessible from this NC-6.
The Master Controller must then be used to access the
installer parameters