background image

 

 

1.3 Codes / Regulations 

 
Brivis ICE units must be installed, serviced or repaired in accordance with these instructions and related regulations, codes, 
standards, and authorities. These include but may not be limited to: 
 

 

Ozone Protection and Synthetic Greenhouse Gas Management Regulations 1995 

 

AS/ NZS 1677.2 - Australian Standard, Refrigeration systems, safety requirements for fixed applications 

 

AS 4211.3 Gas recovery or combined recovery and recycling equipment 

 

HB 276-2004 : A Guide to Good Practice for Energy Efficient Installation of Residential Heating, Cooling & Air 

Conditioning Plant & Equipment 

 

AS 4254 - Ductwork for air-handling systems in buildings 

 

Local Electricity Authority 

 

Local Building Regulations 

 

Environment Authorities 

 

Building Code of Australia (BCA) 

 

Brivis “SuperSizeGuide” 

 
It is recommended the Brivis “SuperSizeGuide” be followed in estimating cooling requirements and for system design that 
will result in efficient installation and provide a higher level of comfort and economical operation. 

 

Brivis assumes no responsibility for equipment installed in violation of any code or regulations and these installation 
instructions.   

 

2.0 Components  
 

Upon receiving units, inspect for damage and ensure appliances match your order.  In the event of damage, or incorrect delivery, notify 
supplier immediately.  Brivis accepts no responsibility for installation of damaged or incorrect units. 

 

2.1 Indoor Unit (Cooling Coil) 
 

Remove packaging from unit and any protective foam packing from coils and pipes. Indoor units are shipped with a holding 
charge of dry nitrogen. Check to confirm the holding charge.  For lifting details refer to the General Arrangement drawings. 

 

 

Brivis Inverter ICE indoor units shall be installed only downstream of a heater 

 

Brivis Inverter ICE is not designed for installation on a marine craft, houseboat, or any similar environment. 

 

Fig. 1 - Indoor Cooling Coil 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Electric Box 

DINXU Series 

P-Trap 
Assembly 

Access Plate  

Power Cord & 
Plug 

Содержание ICE DINXU10Z7

Страница 1: ...er R410A INSTALLATION START UP MAINTENANCE INSTRUCTIONS USER OPERATING GUIDE PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING USING THIS PRODUCT Bonus offer when you register your product online brivis com au ...

Страница 2: ...em and Ductwork Design 11 4 6 Brivis Heater Thermistor position if applicable 11 4 7 Filtration 11 4 8 General Arrangement Drawings 12 5 0 OUTDOOR UNIT INSTALLATION 13 5 1 Location 13 5 2 Electrical Connection 13 5 3 Thermostat Control Wiring 13 5 4 Wiring Diagrams 14 5 5 General Arrangement Drawings Clearance Requirements 17 6 0 REFRIGERATION CHARGE PIPE WORK 18 6 1 Piping Design 19 6 2 Pipe work...

Страница 3: ... the Fan Only 30 1 6 Coded Messages 30 1 7 Locking Unlocking the Networker 31 2 0 SERVICE MAINTENANCE AND WARRANTY 33 Monthly 33 Yearly 33 2 1 Brivis Customer Care Program 33 2 2 Brivis Customer Care Program Membership 34 2 3 ICE Warranty Card Form or Register on line at brivis com au 34 2 4 Terms of Warranty Australia and New Zealand 35 Specifications subject to change without notice 2013 Brivis ...

Страница 4: ... Gas Ducted Heater Specifications for Maximum Recommended Add On Cooling Capacity Table 1 Brivis ICE Models and Heater Compatibility Some heaters may require a transition to modify its starting collar pop size to suit the inlet pop size of the ICE indoor coil DO NOT REDUCE POP SIZES ON INDOOR COIL or HEATER Ensure minimum specified air quantity requirements passes through the ICE cooling coil at a...

Страница 5: ...nts and for system design that will result in efficient installation and provide a higher level of comfort and economical operation Brivis assumes no responsibility for equipment installed in violation of any code or regulations and these installation instructions 2 0 Components Upon receiving units inspect for damage and ensure appliances match your order In the event of damage or incorrect deliv...

Страница 6: ...nit incorporates an evaporator drip tray and is supplied with a 20mm Female Pressure Pipe drain spigot which is to be connected to the P trap supplied Always install the P trap as close to the unit as possible Fill the P trap with water during installation before starting unit to prevent air movement through the drainpipe Ensure trap contains water at all times Adjust the level of the unit to ensu...

Страница 7: ...7 2 4 Outdoor Unit Fig 5 Outdoor Units DONSC10Z7 DONSC13Z7 15Z7 ...

Страница 8: ... measured pressure is less than 400kPa check and if necessary repair any leaks found before proceeding Remove the nitrogen holding charge by connecting a charging line with valve depressor For SWEAT connection Sweat off the liquid suction pipe blanking plates and proceed to pipe up in line with section 6 0 Refrigeration Charge Pipe work For FLARE connection Un screw the flare connection remove the...

Страница 9: ...ling space an additional field supplied Safety Drain Tray shall be installed under the Indoor Unit Safety Tray must also be separately drained arranged to terminate in a position where the home owner can see if water is dripping from the outlet Please instruct the end user to call their Installer or Brivis Service should they notice water dripping from the Safety Tray drain outlet 4 3 Minimum Serv...

Страница 10: ...never be used as their output may be incompatible with or prone to damage the units electronic components Capacity code set The capacity of the indoor unit has been set on the indoor PCB before leaving the factory according to the below table Fig 8 Indoor PCB Toggle Switch Code Capacity Model 8 DONSC10Z7 9 DONSC13Z7 ENC1 Note The capacity has been set before leaving the factory Only fully qualifie...

Страница 11: ... should be at a low level 4 6 Brivis Heater Thermistor position if applicable Mount heater thermistor in the discharge outlet pop of the cooling coil Drill a 3 4 20mm diameter hole through the top of the evaporator coil s outlet pop Carefully insert the thermistor assembly probe end first into this hole and secure using the two screws provided Ensure that the thermistor plug is facing upwards and ...

Страница 12: ...12 4 8 General Arrangement Drawings Fig 9 Indoor Unit Dimensions Model DINXU15Z7 Fig 10 Indoor Unit Dimensions Models DINXU10Z7 DINXU13Z7 ...

Страница 13: ...nnection i e isolating switch and circuit breaker shall be incorporated according to wiring rules Wiring sizing is the responsibility of the installer as it depends on the conditions and regulations applicable to each installation site Refer to the electrical drawings and specifications for electrical data The electrical installation requirements are generally as follows The outdoor unit shall be ...

Страница 14: ...14 5 4 Wiring Diagrams Fig 11 Typical Indoor Unit Wiring Diagram DINXU SERIES Shielded cable Refer to Fig 13 Or to the Classic thermostat shielded ...

Страница 15: ... can be configured for zoning and or Add On Refrigerative Air Conditioning For more information regarding connection to a StarPro unit please refer to the associated heater installer s manual Your zoning requirements may require a Brivis Network 516 module Part No B023178 please refer to the associated heater installer s manual Note For ICE connection to a Brivis SP4 SP5 or SP6 StarPro heater a Br...

Страница 16: ...l Support for information on superseded Brivis Heaters Fig 14 SHEILDED COMMUNICATION CABLE BETWEEN INDOOR AND OUTDOOR UNITS Y G R Electronic Thermostat W HCCA621 Fan Speed G W R EARTH Rc Electronic Control Module Red LED C Y 12AC Fuse 2A INDOOR UNIT ELECTRIC BOX A1 A2 Indoor Unit Electric Box 3 Core Shielded Communication cable ...

Страница 17: ...15 a Outdoor Unit DONSC10Z7 Fig 15 b Outdoor Unit DONSC15Z7 DONSC13Z7 Table 2 Brivis Inverter Outdoor Unit Dimensions Unit mm MODEL A B C D E F H DONSC15Z7 938 633 5 404 448 370 392 1369 DONSC13Z7 938 633 5 404 448 370 392 1369 DONSC10Z7 990 624 366 396 340 345 965 ...

Страница 18: ... starting installation For flare connections please refer to section 6 2 CAUTION Use new clean and sealed refrigeration grade pipe suitable for R410a Keep pipe ends sealed both before and during installation to avoid entry of moisture Suspend pipes with hangers or straps and seal openings around pipe penetrations with flexible material Consider pipe expansion and leave space between pipes and adja...

Страница 19: ...ad insulation and cause easy aging of the material Pipes should be run as directly as possible between indoor and outdoor units If the indoor coil is located above the condensing unit the suction line shall have a loop at the evaporator outlet to prevent refrigerant drainage into the compressor during off cycle see Fig 17 If the evaporator is located below the condensing unit then the suction rise...

Страница 20: ...ssure again released evacuate to a vacuum pressure of 100 microns minimum Disconnect the vacuum pump whilst retaining the system vacuum Open the liquid line valve fully first and then the suction line valve Flare connection Cut the pipe with pipe cutter Insert the flare nut into the pipe and flare the end Refer to the following table for the dimension of flare nut spaces Table 3 Flare Dimensions a...

Страница 21: ...ghten the cap securely and refer to the table for the tightening torque Using the vacuum pump Loosen and remove the service port nuts of stop valves A and B and connect the charging hose of the manifold valve to the service port of isolation valve A Ensure that the isolation valves A and B are both closed Connect the charging hose with the vacuum pump Open the Low side valve of the manifold comple...

Страница 22: ...g the unit and using it to draw refrigerant liquid only through the compressor suction pipe Schrader valve located in the compressor compartment Refer to Section 6 2 Refrigerant containers should be opened slowly to avoid injury Always use protective gloves and protect your eyes when charging refrigerant Additional Refrigerant Charge For pipe lengths greater than 10m an additional 30g m of refrige...

Страница 23: ...emperature LLT between the outdoor coil and indoor unit throttling device in cooling mode Calculate the sub cooling SC CT LLT Measure the outdoor ambient air temperature Measure the indoor return and supply air dry bulb temperatures both before and after the indoor coil Measure the indoor air quantity ensuring it falls within the Indoor Coil s limits Adjust the fan speed to suit the static pressur...

Страница 24: ...erating instructions Ventilation Set the thermostat to the fan only mode The fan only will start and operate continuously Cooling On a call for cooling the compressor and outdoor fan s will start and cycle in response to the thermostat to maintain the desired room temperature The heater s fan will operate continuously or will cycle with compressor depending on the selected fan mode ...

Страница 25: ... 464 Indoor Unit Temperature Dry Bulb C Wet Bulb C Dry Bulb C Wet Bulb C Dry Bulb C Wet Bulb C Air Temperature Entering Outdoor Unit C 21 15 27 19 32 23 TC kW 12 828 13 458 13 699 21 SC kW 9 310 9 765 11 479 TC kW 12 207 12 828 13 208 28 SC kW 9 234 9 699 11 337 TC kW 11 586 12 457 12 958 35 SC kW 9 111 9 547 11 252 TC kW 10 965 11 586 11 956 43 SC kW 9 073 9 348 10 996 TC kW 10 464 11 085 11 456 ...

Страница 26: ...736 Minimum 430 550 620 Rated Airflow Dry Wet 95 118 96 120 88 110 Minimum Airflow Dry Wet 56 70 62 77 62 78 Dimension L x W x H mm 668 x 611 x 542 668 x 611 x 542 680 x 686 x 542 Packing L x W x H mm 750 x 660 x 550 750 x 660 x 550 760 x 740 x 550 Weight Net Gross kg 35 36 35 36 40 41 mm Ф350 Ф400 Ф450 mm Ф350 Ф350 Ф400 L h 2 2 2 9 3 4 mm 20 20 20 Refrigerant pipe connections Liquid Gas mm Ф9 5 Ф...

Страница 27: ... IS LEVEL CHECK FANS FOR ALIGNMENT AND NOISE OPERATION CHARACTERISTICS Please record the following data after at least 20 minutes running time Suction Pressure kPa Suction Line Temperature o C Discharge Pressure kPa Liquid Line Temperature o C Superheat K Sub cooling K Compressor Amps L1 A Indoor coil Air On Return Temperature o C DB Indoor coil Air Off Supply Temperature o C DB Outdoor air Temper...

Страница 28: ...be able to provide the services you request If you have already provided information but have changed your mind and do not want the information used you may make application for access or amendment for that information not to be used You have a right of access to and correction of the information concerning yourself in accordance with the relevant procedures under the Act Enquiries concerning this...

Страница 29: ...ing and cooling modes The PROG Button This button is used to set the Networker s Auto Program settings The Variable Control Buttons These buttons numbered 1 5 have a function when there is text beside the actual button on the display screen Buttons 1 2 4 5 have additional features when used in conjunction with the function button The Rotary Dial This dial is used to alter various settings 1 4 Appl...

Страница 30: ... 6 Coded Messages While the Networker is operating your system it is also monitoring and controlling every aspect of the system s performance If anything unusual occurs the Networker will display a message stating Air Conditioner Fault R01 Code for assistance call the number across the top of the screen There are two parts to the message the R01 number designates which appliance has the fault and ...

Страница 31: ...IN PIN altered Repeat this process to change the other PINs if necessary Remembering that all PINs are set as 1111 by default Pushing the Mode button while you re at the user PIN 1 alteration screen will give access to set user PIN numbers 2 3 If an incorrect number is entered press the Auto button to clear all digits then re enter your user PIN number To exit this area at any time simply press th...

Страница 32: ... default of 1111 is done by entering the Master PIN number 4919 Note The PROG button represents the number 9 in the PIN number So the key sequence is actually Button 4 PROG Button 1 PROG Push the Function button then the Key 2 button immediately after The screen will now display Enter Your PIN number to lock the system Press the M ode button once The screen will now display User PIN number reset E...

Страница 33: ...where necessary Check for vibration and excessive noise Correct where necessary Inspect refrigerant tubing for oil accumulations If oil is detected leak test refrigerant tubing using an electronic leak detector or liquid soap solution Check refrigerant charge by measurement of superheat and sub cooling Where necessary adjust charge to achieve optimum performance Check the tightness of electrical c...

Страница 34: ... _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Site Address if different to above _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ __ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _State _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ Country _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _Post code _ ...

Страница 35: ...re not limited to factory IT Server room telephone exchange processing area e g bakery kitchen warehouse swimming pool agricultural facilities such as a nursery and any Product which has been installed for whatever purpose as a retrofit component to an existing system 9 Purchaser means the end user of the Product the person named as owner in the Warranty certificate the holder of the Proof of Purc...

Страница 36: ...onditions the Purchaser conducts regular and or preventative maintenance as may be specified by Brivis e g Operating Instructions and required by the level of usage and the usage environment including the use of correct and uncontaminated refrigerants and lubricants 3 Conditions of Warranty 3 1 The Purchaser may only obtain the benefit of the Warranty if the Purchaser 3 2 maintains and services th...

Страница 37: ... property arising directly or indirectly from the use or inability to use the Product or any of its parts and servicing the Product are expressly excluded 6 Travel Transport Access Costs 6 1 The Purchaser must pay freight charges in transit insurance expenses and travelling costs for repairs replacements under this Warranty that are required to be performed 100km or more from the nearest Brivis br...

Страница 38: ...uding restricting or modifying those rights Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not am...

Страница 39: ...39 Notes ...

Страница 40: ... 088 AU 24752 Brivis Climate Systems Pty Ltd 2013 All rights reserved No part of these documents may be used in any way or form without prior written consent from Brivis Climate Systems Pty Ltd Specifications subject to change without notice Brivis Climate Systems Pty Ltd 2013 ...

Отзывы: