The unit is pre-wired with a 3-pin plug and lead, and should be plugged into a standard 10 Amp 220 to 240 Volt fixed
switched socket outlet adjacent to the unit, in a convenient location so it can be turned OFF quickly and easily.
The electricity supply must be 220 to 240 Volt at 50 Hz, and from an authorised power supplier. Generators should never
be used, as their output may be incompatible with, or prone to damage the units electronic components.
Capacity code set
The capacity of the indoor unit has been set (on the indoor PCB) before leaving the factory according to the below table:
.
Fig. 8 - Indoor PCB
Toggle Switch Code
Capacity Model
8
DONSC10Z7
9
DONSC13Z7
ENC1
Note:
The capacity
has been set before
leaving the factory.
Only fully qualified
personnel can make
changes.
9
DONSC15Z7
Note:
A qualified electrician must install the 220 to 240 Volt wiring according to local regulations.