2.1 Service Clearances
For servicing, a minimum clearance of 750mm shall be provided on all three sides as shown in Diagram
2, and extend vertically to one meter above the heater roof. Consideration shall be made for flue
terminal location and clearance requirements; refer to heater installation manual.
Diagram 2:
Icebox Service Clearances
2.2 Icebox Supply & Return Air Side
The 10kW Icebox model is available in left hand orientation (DINIB10Z7-L) and right hand orientation
(DINIB10Z7-R). The 13kW and 15kW Icebox is available in left hand orientation from factory with the
capability of being converted to right hand orientation.
Diagram 3:
Icebox Supply & Return Air Side
DINIB10Z7-L
DINIB13Z7
DINIB15Z7
Return Air
Supply Air
Return Air
Supply Air
DINIB10Z7-R
Service Clearance
5
0
0
750
Building Wall
750