INSTALLATION INSTRUCTIONS 

 

1.0 INTRODUCTION 

Read all instructions before proceeding with the installation and start up. 

This equipment must be installed in accordance with all relevant regulatory authority and industry 
requirements.  Only qualified, licensed technicians shall perform works on these units; failure to do so will 
result in warranty being void. 
 

Definitions:  

Shall

” indicates a mandatory requirement of this manual 

Should

” indicates a recommended requirement of this manual 

 
Deviation from these instructions, may at the discretion of Brivis, void the warranty.  As a result, the 
homeowner and or installer may be charged a fee for non-product warranty related call outs. Also note 
that failure to comply with these instructions may preclude Brivis from being able to service the 
appliance. 

 
THE USER SHOULD RETAIN THIS MANUAL FOR FUTURE REFERENCE. 

 

1.1 Brivis ICE R410a Inverter Range  

The  Brivis  Inverter  ICE  series  is  a  refrigerated  cooling  split  only  type  air  conditioner  designed  for 
connection  to  compatible  Brivis  Ducted  Gas  Heaters.    Brivis  Inverter  ICE  utilises  the  heating  system’s 
ductwork and air circulation fan to distribute cool, filtered refrigerated air.  

 

 

ICE  

Outdoor Model  

ICE  

Indoor Model  

Nominal Cooling

 Capacity - kW 

Rated Cooling 

 Capacity - kW 

(Range) 

Recommended Brivis  

Gas Ducted Heater Model 

DONSC10Z7 

DINIB10Z7-L 

10 

9.4 (4.8 -10.1) 

All Buffalo 20XA 

DONSC10Z7 

DINIB10Z7-R 

10 

9.4 (4.8 -10.1) 

All Buffalo 20XA 

DONSC13Z7 

DINIB13Z7 

13 

12.4 (6.3 -13.6 ) 

All Buffalo 26 

DONSC15Z7 

DINIB15Z7 

15 

14.7 (7.5 -16.0) 

All Buffalo 26XA 

 

 

Ensure minimum specified air quantity requirements passes through the ICE cooling coil at all times 

 

Ductwork and fittings must be sized to handle the total cooling airflow through the system on either 
whole home or zoned basis.   

 
 
 

1.2 Safety / Warnings 

The unit is designed to provide safe and reliable service when operating within design specifications.  To 
avoid  injury  to  personnel  and  damage  to  equipment  or  property  when  operating  the  equipment,  the 
following safe practices should be observed as a minimum. 
 

 

Check the unit weight to be sure the lifting equipment is adequate 

 

Disconnect power to the unit before working on it 

 

Do not remove access panels or doors until fans have completely stopped 

 

Do not enter a fan cabinet while the fan is running 

 

Protect materials  when  welding or flame cutting.  Use suitable cloth to contain sparks.  Have a fire 
extinguisher at hand and ready for immediate use 

 

Do not place articles on or against this appliance 

 

Do not use or store flammable materials near this appliance 

 

Do not spray aerosols in the vicinity of this appliance while it is in operation 

 

Do not modify this appliance 

 
 

Note:

 The communication cable installed between the Icebox coil and outdoor unit shall be: 

1.  Field supplied 
2.  3-core shielded cable 
3.  Earthed at the CDU end, refer to Diagram 14. 
 
Failure to do so may prevent the correct operation of the unit 

Table 1: Brivis Icebox models and Heater Compatibility 

 

Содержание DINIB10Z7-L

Страница 1: ...Brivis Inverter Icebox R410A INSTALLATION INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING USING THIS PRODUCT Bonus offer when you register your product online brivis com au ...

Страница 2: ...3 CONDENSATE DRAIN 10 4 4 ELECTRICAL CONNECTION 10 4 5 FLASHING WIRING INSTALLATION 10 4 6 MOUNTING AND SECURE THE HEATER 14 4 7 WIRING THE ICEBOX TO A BX3 BX5 HEATER 15 5 0 SYSTEM AND DUCTWORK DESIGN 16 5 1 FILTRATION 16 6 0 CONDENSER UNIT INSTALLATION 16 7 0 SPECIFICATIONS 17 IMPORTANT NOTICE To be read in conjunction with Brivis ICE Inverter Installation Start Up Maintenance User Operating Guid...

Страница 3: ...C10Z7 DINIB10Z7 R 10 9 4 4 8 10 1 All Buffalo 20XA DONSC13Z7 DINIB13Z7 13 12 4 6 3 13 6 All Buffalo 26 DONSC15Z7 DINIB15Z7 15 14 7 7 5 16 0 All Buffalo 26XA Ensure minimum specified air quantity requirements passes through the ICE cooling coil at all times Ductwork and fittings must be sized to handle the total cooling airflow through the system on either whole home or zoned basis 1 2 Safety Warni...

Страница 4: ...uthority Local Building Regulations Environment Authorities Building Code of Australia BCA Brivis SuperSizeGuide Brivisize It is recommended the Brivis SuperSizeGuide Brivisize be followed in estimating cooling requirements and for system design that will result in efficient installation and provide a higher level of comfort and economical operation Brivis assumes no responsibility for equipment i...

Страница 5: ...nual Diagram 2 Icebox Service Clearances 2 2 Icebox Supply Return Air Side The 10kW Icebox model is available in left hand orientation DINIB10Z7 L and right hand orientation DINIB10Z7 R The 13kW and 15kW Icebox is available in left hand orientation from factory with the capability of being converted to right hand orientation Diagram 3 Icebox Supply Return Air Side DINIB10Z7 L DINIB13Z7 DINIB15Z7 R...

Страница 6: ...e for the 13kW or 15kW Icebox do the following 1 Remove the three screws supporting the Top Rail and relocate to the opposite side 2 Remove the ten screws supporting the Pop Cover Plate and relocate to the opposite side Diagram 4 Changing Supply Return Air Side Top Rail Pop Cover Plate ...

Страница 7: ...efer to the General Arrangement drawings 3 2 Starting Collars Insert starting collar pop into the hole in pop plate ensuring pop flange is placed over the inner supply air wall of the cabinet Spread the pop flange to fit tight in the cabinet s hole with the notch side of the collar over lapping the other Secure the pops with the rivets supplied Rivets Supplied Pop Flange IMPORTANT HEATER FLUE THIS...

Страница 8: ...screws have been supplied in a bag with this installation manual and are required to secure the heater to the Icebox 4 0 ICEBOX INSTALLATION Diagram 8 Typical Icebox Installation Item Description Quantity 1 Heater Support Bracket 1 2 Flashing Top 1 3 Flashing Left Hand 1 4 Flashing Right Hand 1 Model Flashing Kit Number Width 150mm Width 250mm DINIB10Z7 L B062743 B062744 DINIB10Z7 R B062743 B06274...

Страница 9: ...ed at condenser end only 4 1 Location Choose a location that is suitable for refrigeration piping and condensate drainage Adequate provision shall be made available for service access Where the unit is installed the wall of the building shall be capable of effectively anchoring the heater Never put the Icebox coil unit in the return air part of the duct system this may result in condensation formi...

Страница 10: ...ctricity supply shall be 220 to 240 Volt at 50 Hz and from an authorised power supplier Generators should never be used as their output may be incompatible with or prone to damage the unit s electronic components 4 5 Flashing Wiring Installation Note A qualified electrician must install the 220 to 240 Volt wiring according to local regulations Flashing Top Slide 4 Slide the top flashing in from ei...

Страница 11: ...g for cable access Diagram 12 Wiring into the Icebox Diagram 13 Flashing Condensate installation 7 Run a bead of silicone on the flashing faces that will mate with the house 8 Push Icebox into position up against the building wall 9 Install condensate drain Note 3 core shielded communication cable shall be installed from the Icebox unit Terminals Q P E to the condenser unit The shield of the cable...

Страница 12: ...12 Diagram 14 3 Core shielded communication cable between indoor and outdoor units 3 Core Shielded Communication cable P Q E Condenser PCB Shield Icebox PCB ALARM Q E X P Y E ON OFF ...

Страница 13: ...oil Temperature T2B Suction Temperature Field Wiring Control Wiring 240 Wiring Power Supply 240VAC 50Hz 3 Core shielded cable Communication cable from Icebox to condenser For condenser connection refer to Diagram 14 2 Core cable 24VAC from heater or programmable thermostat Note For installation requirements of the outdoor condenser refer to the installation manual supplied with it ...

Страница 14: ...n the bracket to accommodate all heaters and only two are utilised 3 Using suitable screws item 2 field supplied secure bracket to the building wall 4 Remove the six screws from the base of the heater as shown 5 Replace with the six long series screws supplied with the unit 1 2 Diagram 16 Securing heater support bracket Diagram 17 Securing heater to base box Note The Heater Support Bracket can be ...

Страница 15: ...ostat W Rc EARTH For connection refer to installation instruction supplied with B063033 Loom add on relay classic Brivis Networker INDOOR UNIT ELECTRIC BOX M Fn A1 A2 Heater cabinet wall Grommet Icebox PCB relay connections Heater Parameter H01 ID07 5 24VAC NG 2A G W R Electronic Control Module C Y TSTAT TW1 TW2 ZONE ADD ON ZONE A ZONE B 516 Zone Module ZONE B ZONE D Refrig ZONE C ZONE A N O 0V N ...

Страница 16: ...to accept the full air capacity of the system at low noise levels Adequate air filtration must be provided If the system uses high level outlets e g ceiling diffusers then the return air inlet should be at a low level 5 1 Filtration A filter must be fitted into the system and should be easily accessible for regular cleaning Please refer to the guidelines for return air filter grilles accompanying ...

Страница 17: ...17 7 0 Specifications ...

Страница 18: ...18 Notes ...

Страница 19: ...19 Notes ...

Страница 20: ...is Climate System Pty Ltd ABN 64 096 079 088 AU 24752 Issue A Brivis Climate Systems Pty Ltd 2015 All rights reserved No part of these documents may be used in any way or form without prior written consent from Brivis Climate Systems Pty Ltd ...

Отзывы: