15. EXHAUST AND VENTILATION
IMPORTANT
Exhaust fans may be required if insufficient free exhaust area exists. If the exhaust fan is the only
exhaust or ventilation outlet, then its capacity should be at least equal to the Cooler’s air output.
Door = 1�6m²
Hinged Window = 0�3m²
Sliding Window = 0�7m²
Average ventilation area provided by various openings when fully opened�
Brivis Models
Number of average
size windows & doors
(suggestions only)
Highest
Fan
Setting
Lowest
Fan
Setting
Contour
Series
Promina
Series
Advance
Series
Advance
Plus
AD Series
L36
P36
F36D
One door and a hinged
window
1�9 m
2
1�1 m
2
L46
P46
P56
F56D
F46DS
AD56BAL
AD56DBAL
Three sliding windows or
one door & two hinged
windows
2�3 m
2
1�4 m
2
L56
P66
F66DS
AD66/BAL
AD66D/BAL
Four sliding windows or
one door and four hinged
windows
2�8 m
2
1�7 m
2
L66
P76
F76D
Five sliding windows or
one door and five hinged
windows
3�1 m
2
1�9 m
2
L76
F86DS
AD86
AD86D
Six sliding windows or
one door and six hinged
windows
3�4 m
2
2�1 m
2