The motor is not hot, causing the auto-reset thermal overload switch in the fan motor to open circuit�
•
The motor speed sensor has not been damaged or displaced (where fitted).
•
That all electrical connections are secure, and if the motor will not start, call Brivis for service�
14.5 WHAT IF THE PUMP WILL NOT START?
Check:
•
The 10 Amp fuse in the meter box has not blown�
•
The Cooler’s 3-pin supply plug is correctly located in the power socket�
•
For power at the power socket (plug in another appliance and test)�
•
The isolating switches at the unit and the supply power socket are turned ON�
•
The unit is turned ON at the Brivis Networker/Wall Control�
•
The pump is not in a delay due to ServoSeal damper, or tank filling operation (Brivis Promina, Brivis Contour,
Brivis Advance & Brivis AD Dump Models)�
•
The filter basket on the pump is not blocked (Brivis AD only)
•
The pump impellor is not blocked or obstructed�
•
All electrical connections are secure, and if the pump will not start, call Brivis for service�