![British Gas RD 628 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/british-gas/rd-628/rd-628_installation-and-servicing-instructions_2814462023.webp)
Appliance Data Monitoring
If the external Gateway module is fitted, then the operating
system must be commissioned at this stage.
Commissioning of ADM and Gateway
Check if Gateway is plugged into the telephone line and mains.
1
. Remove the cover from the Gateway.
2
. Unplug the power connector from the side of the Gateway.
3
. Reconnect the power to the Gateway. Press and hold
SW1
and
SW2
within 5 seconds of powering up, see Fig. 44.
4
. Observe 2 distinct ‘clicks’ from the relays on the Gateway.
5
. Release the switches. Note only RED LED (RHS) ON. The
Gateway is now reset.
6
. Press
SW1
, observe 0.5 Hz flashing of green LED. The Gateway
is now in “House Address Creation mode” which lasts for approx.
1 minute.
7
. Wait until GREENLED (LHS) flashes 3 seconds ON and 1
second OFF - the Gateway has now created the “House Address”.
8
. Push the switch
SW1
on the ADM while powering up the
appliance, see Fig. 45.
Observe LED on ADM flashing. The flashing rate is 0.5 Hz, the
ADM is now in “House Address Acquisition mode”.
9
. Return to the Gateway and press
SW1
. Observe GREENLED
(LHS) through the side of the box flashing at about 3,4 Hz. The
Gateway is now in “House Address Distribution mode”
“House address Acquisition mode” on the ADM and “House
Address Distribution mode” on the Gateway must overlap. Note
the times are as follows, the ADM will stay in “House address
Acquisition mode” for 100 seconds and the Gateway will stay in
“House address Distribution mode” for 60 seconds.
10
. After 100 seconds from step 8 observe ADM LED flashing at
2 Hz.
11
. After 60 seconds from step 9 observe GREENLED (LHS) on
Gateway ON.
12
. The Gateway will now cause the Gateway to dial into BG. A
click of the relay will be heard from the Gateway at each end of
the dialling in.
13
. Now power down the Heatronic, remove JP1, replace all
covers and power up again.
The system is now set up.
23
Fig. 44. Gateway module
SW1
SW2
LEDs
(Green, Left Hand Side
Yellow, Middle
Red, Right Hand Side)
SW1
LED
Fig. 45. ADM module
SENSOR
Содержание RD 628
Страница 34: ...34 1 2 3 4 7 5 6 8 9 10 11 12 4 15 13 16 19 14 17 18 20 22 23 21 ...
Страница 45: ...45 ...
Страница 46: ...46 ...
Страница 47: ...47 ...
Страница 51: ......
Страница 53: ......
Страница 55: ...L2 0mm ...
Страница 57: ......
Страница 58: ...RD 628 USER INSTRUCTIONS CUSTOMER CARE GUIDE G C NUMBER 47 108 14 ...
Страница 71: ...14 ...