2.3
SETTING UP WITH A DMX512
CONTROLLER
2.3-1 DMX512 ADDRESSING WITHOUT ID ADDRESSING
The figure above shows a simple DMX512
layout with the starting address of the first
unit set at 1, with the second set at 10 and
so on... (Note that when used in this way,
the CH8 ID function must be inactive (CH8=0))
DMX512
CONTROLLER
Connect the DMX512 controller to the units in series.
Each unit has 9 DMX channels so the DMX Addresses should increase by increments of
9 (e.g. 1,10,19,28...)
The ID address has not been set so therefore when using the controller CH8 must
be inactive ( CH8=0 ).
Each DMX Address may be used as many times as required.
Any DMX address in the range from 001 to 500 may be used.
2.3-2 DMX512 ADDRESSING WITH ID ADDRESS
Connect the DMX512 controller to the units in series
Each unit has 9 DMX channels so the DMX Addresses should increase by increments of
9 (e.g. 1,10,19,28...)
Each DMX Address may be used as many times as required.
Any DMX address in the range from 001 to 500 may be used.
Each DMX address may carry up to 66 separate ID addresses.
ID
should be set in the menu on each unit in ascending values
(i.e. 1,2,3...)
ID addresses are accessible from Ch8 on the DMX512 controller.
Example:
8
2007.03.10
2 INSTALLATION
DMX Addr.1
DMX Addr.10
DMX Addr.19
Содержание LED Power Beam