The following functions can be managed remotely: 

No more need to take a ladder and set all units one by one! 

 

DMX START ADDRESS:

 The start address can be set remotely from 001 to xxx.

 

 

PERSONALITY:

 The DMX working mode (DMX-chart) can be set remotely.

 

These  2  functions  make  it  possible  to  prepare  a  complete  DMX-patch  of  all  projectors  on  the  DMX-
controller and send these data to all projectors at once. More functions will be added later. 

 

OPERATING INSTRUCTIONS 

Note: 

when the projector is switched on the display shows “UPDATE WAIT …” This message informs you 

that IF you want to upgrade the firmware, you should do it while this message is shown on the display. For 
normal use you can ignore this message completely. 

A.  Standalone 1unit: 

 

Just connect the projector to the mains. 

 

Select menu option “MASTER” to set the desired light output. 

 

Refer to chapter HOW TO SETUP to learn how to set the other menu options. 

 

B.  Two or more units in master/slave setup: 

 

Connect the units together. Refer to the chapter “electrical installation” to learn how to do this.  

 

Select menu  op

tion “MASTER” to set the desired light output on the master (the first projector in the 

DMX chain) 

 

Set all the other projectors in SLAVE mode 

 

The projectors will now follow the settings of the master projector so they all work synchronously. 

 

C.  Controlled by universal DMX-controller: 

 

Connect all units  together. Refer to the chapter “Electrical installation for two or more units in DMX-
mode” to learn how to do this (don’t forget to address all units properly!)  

 

Connect all units to the mains and turn on the DMX controller. 

Since each unit has its own DMX-address, you can control them individually. Remember that each unit 
uses  1  or  2  DMX-channels,  depending  on  the  DMX-mode  you  have  selected  in  the  menu.  See  the 
different DMX charts below: 

 
DMX Chart for the 1 channel DMX-Mode 

Channel: 

Value: 

Function: 

Remarks: 

000-255 

Master dimmer (0-100%) 

 

 

DMX Chart for the 2 channel DMX-Mode 

Channel: 

Value: 

Function: 

Remarks: 

000-255 

Master dimmer (0-100%) 

 

000-005 

Open 

No strobe 

006-255 

Increasing strobe speed 

006 = slow   255 = fast 

 

MAINTENANCE 

  Make sure the area below the installation place is free from unwanted persons during servicing. 

  Switch off the unit, unplug the mains cable and wait until the unit has been cooled down. 

During inspection the following points should be checked: 

  All screws used for installing the device and any of its parts should be tightly fastened and may not be corroded. 

  Housings,  fixations  and  installations  spots  (ceiling,  truss,  suspensions)  should  be  totally  free  from  any 

deformation. 

  When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The  mains  cables  must  be  in  impeccable  condition  and  should  be  replaced  immediately  when  even  a  small 

problem is detected. 

  In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be cleaned 

monthly. 

  The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize 

light  output.  Cleaning  frequency  depends  on  the  environment  in  which  the  fixture  operates:  damp,  smoky  or 
particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. 

  Clean with a soft cloth using normal glass cleaning products. 

  Always dry the parts carefully. 

Attention: We strongly recommend internal cleaning to be carried out by qualified technician! 

Содержание EXPO CANNON

Страница 1: ......

Страница 2: ......

Страница 3: ...ED refresh rate The lamp behavior can be continuously adjusted from led to halogen Four dimmer curves linear square inverse square S curve In case of DMX failure you can choose between blackout and fr...

Страница 4: ...rd Never let the power cord come into contact with other cables This fixture must be earthed in order to comply with safety regulations Don t connect the unit to any dimmer pack Always use an appropri...

Страница 5: ...d to browse the different menu options or to exit a menu option button used to go to the next menu option or to decrease a parameter value button used to go to the previous menu option or to increase...

Страница 6: ...n openings as this may result in overheating The operator has to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time T...

Страница 7: ...ay Press the ENTER button the values can be changed Use buttons to select the desired DMX512 address The last occupied DMX address is also shown makes it easier to set the address of the next unit in...

Страница 8: ...e halogen lamp behavior At the same time the light output will be instantaneous while pushing a flash button on your DMX controller LOCKING Used to lock the setup menu against unwanted altering of the...

Страница 9: ...are of this unit can be upgraded using a special upgrade tool with Windows software separately available from Briteq Each time the projector is switched on the display shows UPDATE Wait while this mes...

Страница 10: ...ller Since each unit has its own DMX address you can control them individually Remember that each unit uses 1 or 2 DMX channels depending on the DMX mode you have selected in the menu See the differen...

Страница 11: ...manufacturer Mains Input AC 110V 240V 50 60Hz Power consumption 380 Watt max Power Factor 94 Fuse 250V T4A 20mm glass DMX connections 3pin XLR male female DMX channels used 1 2 channels Lamp 37pcs CRE...

Страница 12: ......

Отзывы: