ACR

®

3 MiniPRO™ Hot Bonder 

Temperature Profile Reading and Alarm Settings 

High Shutdown: 

Displays the high temperature shutdown set point 

High Alarm: 

Displays the high alarm set point 

Set point: 

Displays the current system set point 

Actual: 

Displays the current actual control temperature as measured or 

calculated 

Low Alarm: 

Displays the low alarm set point 

Low Shutdown: 

Displays the low temperature shutdown set point 

Thermocouple Readings 

Displays the actual temperature of each individual sensor.  A grey field 
indicates a disabled sensor.  A red field indicates a faulty input: i.e. open, high 
temperature, or low temperature. 

Starting A Program:

 

1.  Attach the necessary cords, sensors and hoses as described in 

Equipment 

Setup and Start-up.

 

2.  Touch 

 button at top of screen to access  the 

OPERATING menu. 

3.  Select the program from the drop down list. 

 

Note: See page 15 for instructions on how to Write a New Program

4.  Touch the 

 button. The Repair Data screen displays. 

5.  Enter the necessary repair data or skip by pressing ENTER. 

6.  To enter the repair data, touch the data field to be entered. 

7.  Using the keyboard on the data entry screen, enter the required data and 

touch ENTER. 

8.  When all necessary data has been entered, press the ENTER button and 

the  program starts. 

© BriskHeat

®

 Corporation.  All rights reserved.

 

 

12 

ACR

®

3 MiniPRO™ Hot Bonder 

Safely Shut Down ACR

®

 3: 

1.  Touch 

 button at the top of the screen to access the 

SYSTEM  menu. 

2.  Touch 

  button. 

3.  Press OK to shut down hot bonder. 

4.  Turn circuit breaker OFF.  

Save a Log File: 

1.  After successful run, Press YES button to save log file and data to USB. 

Press NO button to exit saving only to miniPro unit. 

Silence the Alarm: 

This function silences the audible alarm. 

1.  Touch ALARM button in upper right screen that appears after audible  alarm 

starts. 

Hold a Program: 

This function holds / pauses a program after it has begun. 

1.  Touch HOLD button in the OPERATING menu to hold a program. 

2.  Touch RUN button in the OPERATING menu to resume program. 

Cancel a Program with a Fall: 

This function allows you to cancel a program with a gradual fall. 

1. 

Touch FALL button in the OPERATING menu to cancel program with a fall.

Содержание ACR 3 MiniPRO Hot Bonder

Страница 1: ...while Running 20 Change Program Password 20 System Menu 21 Save a Single Log File to USB Drive 21 Save All Log Files to USB Drive 22 Delete a Single Log File 22 Delete All Log Files 22 Save a Single...

Страница 2: ...ilure to observe these warnings may result in electric shock risk of fire and personal injury or death Inspect hot bonder before use Do not use hot bonder if damaged Do not repair damaged or faulty ho...

Страница 3: ...ply voltage fluctuations up to 10 of the nominal voltage Transient over voltages typically found on a Category II power source i e a lighting circuit Frequency 50 60Hz 20 amps maximum per zone Maximum...

Страница 4: ...insert The connectors are keyed to prevent improper connections 3 Turn the locking ring clockwise 1 2 turn to lock the cord into place The cord must be fully inserted and locked for proper operation R...

Страница 5: ...Version Number The newest version of the software can be found at www briskheat com Do not touch touchscreen with sharp objects or marking objects such as pens pencils markers etc These objects cause...

Страница 6: ...n displays 5 Enter the necessary repair data or skip by pressing ENTER 6 To enter the repair data touch the data field to be entered 7 Using the keyboard on the data entry screen enter the required da...

Страница 7: ...Corporation All rights reserved 14 ACR 3 MiniPRO Hot Bonder Alarms If all conditions are inside the programmed limits while a zone is running the zone tab is green If while running any condition exce...

Страница 8: ...hen ramps down DUAL The hot bonder ramps once to a first set point holds for the programmed length of time ramps to a second set point holds for the programmed length of time then ramps down TRIPLE Th...

Страница 9: ...uples Active thermocouples are indicated by a check mark in the check box next the corresponding thermocouple number Touch the check boxes to remove the check mark from the inactive thermocouples 16 P...

Страница 10: ...1 Access the PROGRAM menu 2 Select the program to delete by touching the drop down menu for STORED PROGRAM NAME 3 Touch DELETE button to delete program 4 Touch YES to confirm BriskHeat Corporation Al...

Страница 11: ...USB Drive This function saves all stored log files to a USB flash disk thumb drive This data can be transferred to a PC for analysis or archiving NOTE The ACR MiniPro Hot Bonder is capable of storing...

Страница 12: ...programs in its internal memory 1 Access the SYSTEM menu 2 Touch LOAD PROGRAMS FROM USB DRIVE button 3 Insert USB flash drive thumb drive in USB port located on the operator console Touch OK button 4...

Страница 13: ...NEW PASSWORD field A keyboard screen appears 8 Re type your new administrator password Touch the ENTER button when done 9 Touch the UPDATE ADMIN PASSWORD button NOTE System is in administrator mode un...

Страница 14: ...under this warranty shall be limited to the repair or replacement at BriskHeat s option of any parts of the product which may prove defective under prescribed use and service following BriskHeat s exa...

Отзывы: