Temperature Profile Reading and Alarm Settings
High Shutdown:
Displays the high temperature shutdown set point
High Alarm:
Displays the high alarm set point
Set point:
Displays the current system set point
Actual:
Displays the current actual control temperature as measured or
calculated
Low Alarm:
Displays the low alarm set point
Low Shutdown:
Displays the low temperature shutdown set point
Thermocouple Readings
Displays the actual temperature of each individual sensor. A grey field
indicates a disabled sensor. A red field indicates a faulty input: i.e. open, high
temperature, or low temperature.
Starting A Program:
1. Attach the necessary cords, sensors and hoses as described in
Equipment
Setup and Start-up.
2. Touch
button at top of screen to access the
OPERATING menu.
3. Select the program from the drop down list.
Note: See page 15 for instructions on how to Write a New Program.
4. Touch the
button. The Repair Data screen displays.
5. Enter the necessary repair data or skip by pressing ENTER.
6. To enter the repair data, touch the data field to be entered.
7. Using the keyboard on the data entry screen, enter the required data and
touch ENTER.
8. When all necessary data has been entered, press the ENTER button and
the program starts.
© BriskHeat
®
Corporation. All rights reserved.
12
ACR
®
3 MiniPRO™ Hot Bonder
Safely Shut Down ACR
®
3:
1. Touch
button at the top of the screen to access the
SYSTEM menu.
2. Touch
button.
3. Press OK to shut down hot bonder.
4. Turn circuit breaker OFF.
Save a Log File:
1. After successful run, Press YES button to save log file and data to USB.
Press NO button to exit saving only to miniPro unit.
Silence the Alarm:
This function silences the audible alarm.
1. Touch ALARM button in upper right screen that appears after audible alarm
starts.
Hold a Program:
This function holds / pauses a program after it has begun.
1. Touch HOLD button in the OPERATING menu to hold a program.
2. Touch RUN button in the OPERATING menu to resume program.
Cancel a Program with a Fall:
This function allows you to cancel a program with a gradual fall.
1.
Touch FALL button in the OPERATING menu to cancel program with a fall.