BACKGROUND INFORMATION ON PERIODIC COOLING

 

 
 
 
The precise details of which days and what cooling period each day should be used for best effect are not known. Brinsea have assessed 
the  available  research  and  suggest  that poultry,  water  fowl  and  game  bird eggs  have  a  30  minute daily  cooling period  from  day  7 
through to 2 days before eggs are due to hatch (the same point that automatic turning would normally be stopped). 
 

  

 

COOLING  IS  NOT  RECOMMENDED  FOR  PARROTS  AND  BIRDS  OF  PREY  BECAUSE  THE  RESULTS  OF  COOLING  HAVEN’T  YET  BEEN 
ESTABLISHED

. For further details please visit the Brinsea website at www.brinsea.co.uk/cooling 

 
 

 
 

HOW IT WORKS WITH YOUR INCUBATOR

 

 
 

 

The periodic cooling feature turns the incubator’s heater and low temperature alarm off for a selectable period but keeps the 
fan running. After the cooling period is complete the incubator reverts to normal temperature and the alarm is automatically 
reset. 

 

Each cooling period starts at approximately the same time each day (24 hours between start times). The first cooling period 
will start 24 hours after the incubator was last switched on. If there is a power interruption the 24 hour delay starts again. 

 

During  the  cooling  period  the  heater  asterisk  goes  off  and  an  arrow  “↓”  is  displayed.  When  the  cooling  period  ends  the 
asterisk is  shown and the incubator warms to incubation temperature. The time taken  to return  to incubation  temperature 
depends on the room temperature and may take 30 or more minutes. 

 

The humidity pump will not run during periodic cooling; humidity levels will rise as the air cools. 

 

 

8 PERIODIC INCUBATION COOLING

 

 

 

SETTING THE COOLING PERIOD

 

 

The cooling function is not essential. It’s an optional 
feature  that  may  be  adjusted  for  breeders  wishing 
to experiment. The factory default is set to “cooling 
OFF”. 

Do  not  use  before  day  7  of  incubation  or 

whilst hatching.  

 

 

1.

 

Press  the  -  and  +  buttons              
simultaneously  to  unlock  the 
Main Menu. 

 
 

2.

 

Press the + button to scroll to the 
cooling option. 

 

3.

 

Press  OK  to  select  the  cooling 
screen. Use the + and – buttons to 
select OFF or 10 to 360 minutes of 
cooling. 

 
 

4.

 

Press OK to accept the figure and 
then scroll to SAVE and press OK 
to save the changes. 

 

 

Содержание Ovation 28 EX

Страница 1: ......

Страница 2: ...for future reference This document includes recommended procedures for successful hatching but incubation involves the control and manipulation of a large number of factors and in certain circumstances different procedures may be necessary For more detailed information on all aspects of egg incubation including helpful advice on getting best results please visit our website at www brinsea com Your...

Страница 3: ...bly Pump Setup Location Installation 2 Product Introduction Functional Features 3 Settings Control Menu 4 Display 5 Temperature 6 Humidity and Ventilation 7 Eggs 8 Periodic Incubation Cooling 9 Hatching Cleaning up 10 Specifications CONTENTS 4 5 6 9 11 12 13 14 16 17 19 20 21 22 ...

Страница 4: ...m the incubator and parts Retain the carton and packing materials to enable the unit to be repacked 1 Remove the packaging and lift off the top of the incubator 2 Remove the card packing inserts and elastic bands from inside the incubator 3 Check that the electrical supply matches the machine s requirements marked on the technical label inside the clear top 1 2 ...

Страница 5: ... part If there are any parts damaged or missing please contact your retailer or Brinsea Products at the address at the end of the document Damaged appliances must not be used 1 Long Pump Connector 2 Water Pump Tubing 4 3 110mm 3 Short Pump Connector 4 Pump Cover 5 Top 6 Egg Carriers 4 7 Link 8 Water Pan Covers 2 9 Water Evaporation Block 10 Base 11 Silicon Water Tubing 10 3m 7 10 9 11 ...

Страница 6: ... water pans Fit the water evaporation block into the correct water pan This is the one that has the water channel flowing into it 2 Place the water pan covers into their positions in the base Do not add any water to the water pans 2 Water Channel 1 Water Evaporation Block ...

Страница 7: ...NG UP YOUR INCUBATOR ASSEMBLY 3 Fit the link into its slots ensuring the smooth side is facing inwards 4 Fit the egg carriers into the supports The pegs must fit in the sockets 3 4 Link slots Detail A Detail B Detail A Detail B ...

Страница 8: ...ound the base edge 6 Find a suitable water container 1pt to 2pt Place next to the incubator IMPORTANT Do not place the water container on top of the incubator or higher than the incubator This is to prevent the water siphoning through and flooding the incubator The water container is best placed next to the incubator on the same surface Please ensure the incubator is used on a water resistant surf...

Страница 9: ...3 110mm and two pump connectors that are fitted at each end of the tube Use the tube diagram to ensure your tube is cut to the correct length 1 Ensure the long pump connector is in the correct position with the nozzle passing through the slot into the incubator as shown 2 Cut the water container tube to length a length of silicon water tubing to connect the pump to the water container Leave enough...

Страница 10: ...screw Check the water level in your water container regularly Please check the condition of the tube after each use The peristaltic pump will need to have its water pump tube replaced about every 3 months Cut a length of tube to 4 3 110mm Remove the connectors and pull off the old tube Replace with the new tube avoiding twists Use the diagram on the product to assist and follow the instructions ab...

Страница 11: ...he same time Ensure that the room temperature cannot drop on a cold night Ideally thermostatically control the room at between 68 and 77 F 20 and 25 C Never allow the room temperature to drop below 63 F 17 C Make sure that the incubator cannot be exposed to direct sunlight and is used on a flat level surfaced worktop or table not on the floor Connect the mains cable to the incubator lid Ensure the...

Страница 12: ...12 AF37 US Issue 01 2 PRODUCT INTRODUCTION FUNCTIONAL FEATURES 1 Digital Display 2 Pump Cover 3 Control Buttons 4 Adjustable air vent 5 Egg Carriers 4 3 1 4 2 5 ...

Страница 13: ...TURE ALARM Range 1 0 5 0 C 1 8 9 0 F below set incubation temperature Default 3 0 C 5 4 F See section 4 CELSIUS FAHRENHEIT DISPLAY Switches all temperature figures between C and F Default C See section 5 SAVE All changes are saved Return to normal operation screen CANCEL All changes are ignored Return to normal operation screen TURNING MODE Switches the turning system on or off Default ON TURNING ...

Страница 14: ...ed humidity level in the incubator If turning is switched off an O flashes at the corner of the display If turning is switched on a line symbol rotates at the corner of the display Changing Settings The Control Menu allows the various settings to be modified and saved All settings are retained in the event of a power cut To access the Control Menu press the and buttons simultaneously to unlock the...

Страница 15: ...to candle eggs a number of times after this event to check for losses Low Room Temperature Alarm FIG 4 If the calculated room temperature remains too low for optimum results for more than 1 hour a warning is displayed RM and an alarm will sound Press OK to silence the alarm for 30 minutes If the low temperature problem rectifies itself the RM remains on the display to show this has happened Press ...

Страница 16: ...perature in the menu to suit the types of eggs you are incubating As the incubator warms up and approaches its control setting the heater on asterisk will change from continuously on to flashing Allow the incubator to stabilise for at least an hour before adjusting the temperature Recommended temperatures Typical incubation period Hens 99 3 99 6 F 37 4 37 6 C 21 days Pheasant 99 6 100 0 F 37 6 37 ...

Страница 17: ... eggs periodically during incubation it is possible to monitor and if necessary correct humidity levels to achieve the correct weight loss For more detailed information on all aspects of egg incubation including helpful advice on getting best results please visit our website at www brinsea com brochures BrinseaIncubationHandbook2016 pdf 6 HUMIDITY AND VENTILATION UNDERSTANDING HUMIDITY Short term ...

Страница 18: ... the minimum and maximum levels of humidity achievable in an incubator depend upon several factors including the ambient conditions in the incubation room You may need to allow 24 hours for humidity to fully stabilise after making changes If you cannot achieve the relative humidity level required consider these notes Humidity will not go low enough The humidity control system can only increase hum...

Страница 19: ...n such as Brinsea Incubation Disinfectant Concentrate following the manufacturer s instructions It is essential to wash eggs in solution which is significantly warmer than the egg Bear in mind that all solutions will remove the outer cuticle from the egg as well as the dirt and may leave the egg at greater risk from bacterial contamination in the future The Ovation 28 EX is designed to accommodate...

Страница 20: ...me time each day 24 hours between start times The first cooling period will start 24 hours after the incubator was last switched on If there is a power interruption the 24 hour delay starts again During the cooling period the heater asterisk goes off and an arrow is displayed When the cooling period ends the asterisk is shown and the incubator warms to incubation temperature The time taken to retu...

Страница 21: ...on Disinfectant Solution and then rinse thoroughly Use a vacuum cleaner and soft brush to remove dust from the fan guard Wipe all other internal surfaces with a cloth made damp with the solution and then wipe off with a cloth made damp with clean water Ensure that the instructions supplied with the fluid are followed If a separate hatcher is used the procedure above should still be followed every ...

Страница 22: ...Watts Electrical Supply 230v 50Hz or 115V 60Hz as ordered 7 hen eggs in hen egg carrier 7 duck eggs in hen egg carrier 22 quail eggs in optional large egg carrier 19 pheasant eggs in optional large egg carrier The large egg carriers are available from brinsea com or your local stockist product code AF011 Brinsea Products Inc 704 N Dixie Ave Titusville FL 32796 2017 USA Phone 321 267 7009 Toll Free...

Отзывы: