14
AF37 US Issue 01
4 DISPLAY
DIGITAL CONTROL SYSTEM
The Ovation EX control system utilises a highly
accurate, individually calibrated sensor for
temperature. Be cautious of low cost analogue or
digital thermometers when comparing them with
the incubator display reading.
(FIG 1)
Normal Operation
– Temperature, relative humidity and turn system status are continuously displayed.
The asterisk “*” adjacent to the temperature reading shows when the heater power is on. When warming the asterisk will be
continuously on, once warmed up the asterisk will slowly flash as the heater is pulsed to maintain the correct temperature.
When reducing the temperature setting the asterisk may go off, this is normal.
During periodic incubation cooling (see section 8) the asterisk will be replaced by an arrow: “↓”.
The asterisk "*" adjacent to the humidity reading shows when the pump output is active (see section 8). The pump output will
not come on until the incubator is up to operating temperature and the set humidity level is greater than the measured
humidity level in the incubator.
If turning is switched off an “O” flashes at the corner of the display.
If turning is switched on a line “/” symbol rotates at the corner of the display.
Changing Settings
– The Control Menu allows the various settings to be modified and saved. All settings are retained in the
event of a power cut.
To access the Control Menu press the
+
and
–
buttons simultaneously to unlock the display. For full details of menu settings
please refer to the contents on page 3 and view the relevant sections.
Power Loss Display (FIG 1)
-- If power has been interrupted due to a power cut (or when first switching on) a “P” is shown
flashing in the corner of the display. Press OK for 2 or more seconds to clear the indicator. If the reason for the power loss is not
known check the power cable connections are secure.
Once the “P” indicator has been cleared, it is advisable to candle eggs a number of times to check for losses.
T*37.5
C
H 35%
P/
T*37.5
C
H 35%
T*37.5C
H 35% P/
Example settings for poultry:
Temperature:
99.5°F (37.5
°C)
Humidity:
45%
Turning interval:
45 minutes (turn off
from day 19 and remove egg carriers)
Cooling:
OFF
(Do not manually add water to the water
pans when
the automatic humidity
control system is being used)