LIGHTING INSTRUCTIONS:
Follow the instructions exactly.
1. Make sure the regulator control knob and cylinder valve are in the OFF positions.
2. Turn on the fuel supply by rotating the cylinder valve counterclockwise to full open.
3. DO NOT stand with head, body, or arms over the cooker when lighting.
4. Insert paper match in match holder prior to striking. Strike and place match through lighting hole to
approximately 1/2" (1 to 2 cm) from the burner. We recommend the use of a long wooden match.
5. Slowly turn regulator control knob clockwise until burner lights.
6. If burner does NOT ignite immediately, turn the regulator control knob and cylinder valve to OFF, wait
5 minutes for gas to evacuate and repeat Steps 1 through 4 until burner ignites.
7. If the burner does not light within the first few attempts, there is a problem with the gas supply. Turn
off the gas at the burner and cylinder.
DO NOT
attempt to operate the cooker until the problem is
found and corrected.
HOW TO REIGNITE BURNER:
It is recommended to place lid over cooking vessel before reigniting burner to prevent liquid splashing on
you as you reignite burner. Follow Steps 1 through 4 above, to reignite burner. Use caution when lighting
burner, hot liquid from cooking vessel may have splattered and run down the sides of the unit.
BURNER FLAME CHECK
Adjust flame height using regulator control
knob. Rotate air shutter to achieve mostly
blue flame. The air damper mounted on the
back of your burner helps to control the amount
of air that mixes with the LP gas. A blue flame
with little or no yellow flame provides the
best heat. Adjust the air damper until the
desired flame is achieved.
NOTE:
Make sure the male fitting on the cooker is screwed into the air shutter and tightened securely. Do
not over-tighten as the air shutter needs to move freely in order to adjust air intake. Check the
attachment for proper connection every time propane tank is connected to cooker.
10
Yellow
Blue
Burner Hole
Rotating
Air Shutter
Air Hole
Match Holder
IMPORTANT SAFEGU
ARD
• DO NOT
REMO
VE T
HIS
TAG
•
TURN
GAS O
N AN
D OFF
USIN
GVAL
VE ON L.P. GAS
TAN
K. USE THIS RED
CONTROL VAL
VE FOR
FLAME ADJUSTMENT ONLY.
Lighter Hole
Regulator Control Knob