In case the cover is manual, the user must set the equipment side switch to the position "II"
whenever the pool is covered.
5.6
Disinfection Recommendations
It is advisable to disinfect it overnight. In fact, ultraviolet radiation acts on the chlorine
produced by the electrolysis cell, catalyzing salt regeneration (which is why salt consumption is
insignificant). If disinfection is carried out overnight, the chlorine concentration rises rapidly and
the disinfecting effect is much more effective.
For good disinfection practice it is also advisable to maintain a concentration of chlorine stabilizer
(isocyanuric acid) of 35 ppm; i.e., 35 g / m 3 of water. This concentration, although reduced, allows
to diminish the diurnal losses of chlorine by the effect of ultraviolet radiation.
6
Configuration and Calibration
All equipment are supplied properly configured and calibrated at the factory so that it is not
necessary to use these operations at the time of installation.
If you wish to change the factory settings or need to calibrate the ORP current or probe, proceed
as described in the following chapters.
To enter the Setup / Calibration menu, move the side switch to position II and press the Command
Button
for 5 seconds until the display shows:
Figure 9 – Calibration / Configuration Menu
Select what you want to configure / calibrate by briefly pressing the Command Button
until
the "<=>" symbol is below the desired option: C.I. - for calibration of the cell current; C.O - for
ORP calibration; L.O - for setting the ORP limits; INV - for setting the polarity reversal time.
Once the desired option has been selected press the Command
for 5 seconds to enter the
respective operation.
6.1
Current Calibration
IMPORTANT NOTICE: This function should only be carried out by trained and qualified
personnel. Lets you check the current being passed in the cell and re-calibrate the equipment if
necessary.
Before calibration, make sure that the salinity level of the water is the desired (never less than 5g
/ l) and that the temperature is equal to or greater than 20 ° C.
To enter the current setting, select C.I in the Calibration / Configuration menu (see chapter 6).
When entering calibration the following information will appear on the screen: