characteristics of the water, namely its calcium hardness. The higher the water hardness, the lower 
the  defined  range  should  be,  to  ensure  that  no  encrustation  occurs  on  the  titanium  plates. 
The  equipment  is  factory  set  at  6H  and  can  be  changed  to  a  range  between  3H  and  8H. 
IMPORTANT:  the  shorter  the  inversion  time  the  shorter  the  lifetime  of  the  electrolysis  cell. 
To change the polarity inversion, select the INV option in the Calibration / Configuration menu 
(see chapter 6). 
  
When you enter the menu, the following screen appears: 
 
 
 
 
  
 

Figure 18 - Polarity Inversion Time 

 
 

To change the value, briefly press the Command Button 

 to set the desired time. To record 

press the Command Button 

 for 5 seconds. 

 
The "Test Inv" option is used to run a diagnostic test to verify that both polarities work. When you 
choose  this option, the system will start one of the polarities for a few seconds, then  stop tp 
reverse and stars again on the other polarity. 
 
 
 

7

 

Alarms 

7.1

 

Alarm 1 - Low Flow 

 

This alarm (ALARM 1) is released if there is not sufficient water flow in the electrolysis cell. 

When the alarm is triggered, the system goes into standby to safeguard the integrity of the 
equipment. It should be verified that: 
• All valves are correctly positioned 
• There are no hydraulic leaks 
• The filter is in the filtering position 
Once the problem has been corrected the alarm will be automatically deactivated. 
 
 

7.2

 

Alarm 2A - High Salt 

 

This alarm (ALARM 2A) is released when the electrolysis reaches the maximum threshold of 

130%. This is indicative that the concentration of salt in the pool is above the  maximum value 
advisable for the preservation of the cell. The amount of salt to be reduced must be inferred by 
the volume of water in the pool. It should be verified that: 
 
• The salt concentration in the water is between 4 to 5 g / l 
• The salt in the water is completely diluted 
• The power supply of the cell is well regulated 
• The equipment is correctly calibrated  
 
Once the problem has been corrected, you must restart the machine to disable the alarm. 
 

Содержание COLIBRI RX

Страница 1: ...COLIBRI RX PLUMA RX SALT CHLORINATOR...

Страница 2: ......

Страница 3: ...al Probe 7 5 5 Operation with Pool Coverage 7 5 6 Disinfection Recommendations 8 6 Configuration and Calibration 8 6 1 Current Calibration 8 6 2 ORP Calibration 9 6 3 Setting ORP Limits 10 6 4 Polarit...

Страница 4: ...oller s door open to stabilize temperature and avoid condensation of the electronic components When the controller is turned on remember to let the capacitors discharge before handling them to avoid e...

Страница 5: ...ell can be installed horizontally or vertically In the vertical installation the electrical wires must be faced upwards to allow for the buildup of gases originated from the electrolysis process on th...

Страница 6: ...d under the left side External Controller Instalattion optional 4 2 3 External Controller Installation Optional If you choose to connect an external controller it must emit a potential free signal whi...

Страница 7: ...olysis as a percentage of filtering time in order to increase or decrease production and always choose the best reality of the swimming pool in which the equipment is installed Pressing the control bu...

Страница 8: ...l time chlorine readout ORP _____ mV is displayed on the machine s display In this mode chlorine production should be set to P100 and ORP limits for the range that best fits the pool reality where the...

Страница 9: ...nstallation If you wish to change the factory settings or need to calibrate the ORP current or probe proceed as described in the following chapters To enter the Setup Calibration menu move the side sw...

Страница 10: ...have all the necessary material including a glass of water and absorbent paper in order to clean the probe before introducing the buffers To enter the ORP calibration select the C O option in the Cali...

Страница 11: ...its To set the limits briefly press the Command Button and appears Figure 15 Definition of Upper Limits To change the value briefly press the Command Button to set the desired limit The upper limit ca...

Страница 12: ...or a few seconds then stop tp reverse and stars again on the other polarity 7 Alarms 7 1 Alarm 1 Low Flow This alarm ALARM 1 is released if there is not sufficient water flow in the electrolysis cell...

Страница 13: ...arm 3 Low ORP This alarm ALARM 3 is triggered when the ORP reading is greater than 0mV and less than 150mV and is used to indicate that the chlorine level in the water is too low or that the ORP probe...

Страница 14: ...lysis cell 5 years for the electronic equipment Twelve months for temperature probes except ware out PLUMA 2 years or 10 500h of operation for the electrolysis cell 2 years for the electronic equipmen...

Страница 15: ...s and investment in its country Bright Blue does not take responsibility for any delay or fault caused by circumstances outside its control Possible situation include but are not limited to interrupte...

Отзывы: