characteristics of the water, namely its calcium hardness. The higher the water hardness, the lower
the defined range should be, to ensure that no encrustation occurs on the titanium plates.
The equipment is factory set at 6H and can be changed to a range between 3H and 8H.
IMPORTANT: the shorter the inversion time the shorter the lifetime of the electrolysis cell.
To change the polarity inversion, select the INV option in the Calibration / Configuration menu
(see chapter 6).
When you enter the menu, the following screen appears:
Figure 18 - Polarity Inversion Time
To change the value, briefly press the Command Button
to set the desired time. To record
press the Command Button
for 5 seconds.
The "Test Inv" option is used to run a diagnostic test to verify that both polarities work. When you
choose this option, the system will start one of the polarities for a few seconds, then stop tp
reverse and stars again on the other polarity.
7
Alarms
7.1
Alarm 1 - Low Flow
This alarm (ALARM 1) is released if there is not sufficient water flow in the electrolysis cell.
When the alarm is triggered, the system goes into standby to safeguard the integrity of the
equipment. It should be verified that:
• All valves are correctly positioned
• There are no hydraulic leaks
• The filter is in the filtering position
Once the problem has been corrected the alarm will be automatically deactivated.
7.2
Alarm 2A - High Salt
This alarm (ALARM 2A) is released when the electrolysis reaches the maximum threshold of
130%. This is indicative that the concentration of salt in the pool is above the maximum value
advisable for the preservation of the cell. The amount of salt to be reduced must be inferred by
the volume of water in the pool. It should be verified that:
• The salt concentration in the water is between 4 to 5 g / l
• The salt in the water is completely diluted
• The power supply of the cell is well regulated
• The equipment is correctly calibrated
Once the problem has been corrected, you must restart the machine to disable the alarm.