10 

 

6.3

 

Setting ORP Limits 

This  menu  allows  you  to  configure  the  ORP  (HIGH)  and  minimum  (LOW)  limits  to 

determine the correct concentration of chlorine in the water. The value of ORP is not the same 
from pool to pool being dependent on factors external to the equipment, so the correct limits 
should  be  checked  case  by  case  in  the  pool  where  the  equipment  is  installed. 
To  set  the  ORP  limits,  choose  L.O  in  the  Calibration  /  Configuration  menu  (see  Chapter  6). 
 
When you enter the menu, the following screen appears: 
 
 
 
  
 

Figure 14 - Change in ORP Limits 

 

To set the limits, briefly press the Command Button 

 and appears:  

 
  
 
 
 

Figure 15 - Definition of Upper Limits 

 

 

To change the value, briefly press the Command Button  

 to set the desired limit. The upper 

limit can be set between 600mV and 800mV at 50mV intervals. To save the desired value, press 
the Command Button 

 for 5 seconds and move to the lower limit setting. 

 
 
 
 
 
 

 

  Figure 16 - Definition of Lower Limits 

 

 

Repeat the previous steps and record. After the operation is completed, the following screen 
appears: 
 
  
 
 
 

 Figure 17 - New Limits of ORP 

 

 

 

6.4

 

Polarity Inversion Setting 

 

The polarity inversion process is responsible for the self cleaning of the electrolysis cell in 

order  to  ensure  that  it  does  not  accumulate  limestone,  consequently  losing  its  production 
capacity. 
 
The  correct  time  interval  between  each  inversion  of  polarity  depends  on  the  chemical 

Содержание COLIBRI RX

Страница 1: ...COLIBRI RX PLUMA RX SALT CHLORINATOR...

Страница 2: ......

Страница 3: ...al Probe 7 5 5 Operation with Pool Coverage 7 5 6 Disinfection Recommendations 8 6 Configuration and Calibration 8 6 1 Current Calibration 8 6 2 ORP Calibration 9 6 3 Setting ORP Limits 10 6 4 Polarit...

Страница 4: ...oller s door open to stabilize temperature and avoid condensation of the electronic components When the controller is turned on remember to let the capacitors discharge before handling them to avoid e...

Страница 5: ...ell can be installed horizontally or vertically In the vertical installation the electrical wires must be faced upwards to allow for the buildup of gases originated from the electrolysis process on th...

Страница 6: ...d under the left side External Controller Instalattion optional 4 2 3 External Controller Installation Optional If you choose to connect an external controller it must emit a potential free signal whi...

Страница 7: ...olysis as a percentage of filtering time in order to increase or decrease production and always choose the best reality of the swimming pool in which the equipment is installed Pressing the control bu...

Страница 8: ...l time chlorine readout ORP _____ mV is displayed on the machine s display In this mode chlorine production should be set to P100 and ORP limits for the range that best fits the pool reality where the...

Страница 9: ...nstallation If you wish to change the factory settings or need to calibrate the ORP current or probe proceed as described in the following chapters To enter the Setup Calibration menu move the side sw...

Страница 10: ...have all the necessary material including a glass of water and absorbent paper in order to clean the probe before introducing the buffers To enter the ORP calibration select the C O option in the Cali...

Страница 11: ...its To set the limits briefly press the Command Button and appears Figure 15 Definition of Upper Limits To change the value briefly press the Command Button to set the desired limit The upper limit ca...

Страница 12: ...or a few seconds then stop tp reverse and stars again on the other polarity 7 Alarms 7 1 Alarm 1 Low Flow This alarm ALARM 1 is released if there is not sufficient water flow in the electrolysis cell...

Страница 13: ...arm 3 Low ORP This alarm ALARM 3 is triggered when the ORP reading is greater than 0mV and less than 150mV and is used to indicate that the chlorine level in the water is too low or that the ORP probe...

Страница 14: ...lysis cell 5 years for the electronic equipment Twelve months for temperature probes except ware out PLUMA 2 years or 10 500h of operation for the electrolysis cell 2 years for the electronic equipmen...

Страница 15: ...s and investment in its country Bright Blue does not take responsibility for any delay or fault caused by circumstances outside its control Possible situation include but are not limited to interrupte...

Отзывы: