©Copyright
FR-V2016
Les informations contenues dans ce document peuvent être modifiées sans préavis.
10
6.3
Setting ORP Limits
This menu allows you to configure the ORP (HIGH) and minimum (LOW) limits to
determine the correct concentration of chlorine in the water. The value of ORP is not the same
from pool to pool being dependent on factors external to the equipment, so the correct limits
should be checked case by case in the pool where the equipment is installed.
To set the ORP limits, choose L.O in the Calibration / Configuration menu (see Chapter 6).
When you enter the menu, the following screen appears:
Figure 14 - Change in ORP Limits
To set the limits, briefly press the Command Button
and appears:
Figure 15 - Definition of Upper Limits
To change the value, briefly press the Command Button
to set the desired limit. The upper
limit can be set between 600mV and 800mV at 50mV intervals. To save the desired value, press
the Command Button
for 5 seconds and move to the lower limit setting.
Figure 16 - Definition of Lower Limits
Repeat the previous steps and record. After the operation is completed, the following screen
appears:
Figure 17 - New Limits of ORP
6.4
Polarity Inversion Setting
The polarity inversion process is responsible for the self cleaning of the electrolysis cell in
order to ensure that it does not accumulate limestone, consequently losing its production
capacity.
The correct time interval between each inversion of polarity depends on the chemical