Briggs & Stratton InfoHub 6520 Скачать руководство пользователя страница 2

2 BRIGGSandSTRATTON.COM

Save These Instructions

Important Safety Instructions 

SAVE THESE INSTRUCTIONS - This manual contains 

important instructions that should be followed during 

installation and maintenance of the generator and 

batteries.

Safety Symbols and Meanings

 The safety alert symbol indicates a potential personal 

injury hazard. A signal word (DANGER, WARNING, or 

CAUTION) is used with the alert symbol to designate a 

degree or level of hazard seriousness. A safety symbol 

may be used to represent the type of hazard. The signal 

word NOTICE is used to address practices not related to 

personal injury. 

 

DANGER

 indicates a hazard which, if not avoided, will 

result in death or serious injury.

 

WARNING

 indicates a hazard which, if not avoided, 

could result in death or serious injury.

 

CAUTION

 indicates a hazard which, if not avoided, 

could result in minor or moderate injury.

NOTICE

 Addresses practices not related to personal injury

The manufacturer cannot anticipate every circumstance 

that might involve a hazard. The warnings in this manual, 

and the tags and decals affixed to the unit are, therefore, 

not all-inclusive. If you use a procedure, work method 

or operating technique that the manufacturer does not 

specifically recommend, you must satisfy yourself that it is 

safe for you and others. You must also make sure that the 

procedure, work method or operating technique that you 

choose does not render the generator system unsafe.

NOTICE  

Improper treatment of equipment could damage it 

and shorten its life.

•  Use equipment only for intended uses.

•  If you have questions about intended use, ask dealer or 

contact Briggs & Stratton.

•  Do not expose equipment to excessive moisture, dust, dirt, or 

corrosive vapors.

•  Remain alert at all times while working on this equipment. 

Never work on the equipment when you are physically or 

mentally fatigued.

•  If connected devices overheat, turn them off and turn off their 

circuit breaker/fuse.

Read Manual

Electrical Shock

 

WARNING

  Shock Hazard. Installing low and high voltage 

wire in same conduit could result in death, serious 

injury and/or property damage.

•  Do not run low and high voltage wire in the same conduit 

unless the insulation rating on ALL wiring is rated for 600V. 

See NEC for more information.

 

WARNING  

Failure to properly ground equipment could 

cause electrocution resulting in death or serious injury.

 

•  Do not touch bare wires.

•  Do not use equipment with worn, frayed, bare or otherwise 

damaged wiring.

•  Do not handle electrical cords while standing in water, while 

barefoot, or while hands or feet are wet.

•  If you must work around a unit while it is operating, stand on 

an insulated dry surface to reduce shock hazard.

•  Do not allow unqualified persons or children to operate or 

service equipment.

•  In case of an accident caused by electrical shock, immediately 

shut down all sources of electrical power and contact local 

authorities. Avoid direct contact with the victim.

 

WARNING

  Equipment contains high voltage that could 

cause electrocution resulting in death or serious injury. 

•  Despite the safe design of the system, operating this 

equipment imprudently, neglecting its maintenance or being 

careless could result in death or serious injury.

 

WARNING  

This product contains lead and lead 

compounds, known to the state of California to cause 

birth defects or other reproductive harm. Wash 

your hands after handling this product. Cancer and 

Reproductive Harm - www.P65Warnings.ca.gov

Содержание InfoHub 6520

Страница 1: ...ify Power Management System Installation and Operation Instructions Questions Help is just a moment away Call our Helpline 800 732 2989 M F 8 5 CT Copyright Briggs Stratton Corporation Milwaukee WI US...

Страница 2: ...ontact Briggs Stratton Do not expose equipment to excessive moisture dust dirt or corrosive vapors Remain alert at all times while working on this equipment Never work on the equipment when you are ph...

Страница 3: ...isfying RF exposure compliance This device meets exposure limits as demonstrated in a RF Exposure Analysis The device must be installed such that a minimum separation distance of 20 cm is maintained b...

Страница 4: ...Connections K Service port serial The wireless module can be installed wherever it is convenient and a good wireless signal is present either an indoor or outdoor location The wireless gateway module...

Страница 5: ...LED J Relay LED K Fault LED L Network LED A 24VAC Power Input B Network Configuration Button Join C Load 2 Output D Load 1 Output E Fault LED F Network LED G Power LED H Output 2 LED J Output 1 LED G...

Страница 6: ...circuit breaker to OFF 3 Remove the fuse from the main generator 4 Utility voltage is present at generator control panel Remove the fuses from the transfer switch to disconnect power before servicing...

Страница 7: ...the Amplify Power Management System to allow wireless connection You must pair the devices to be able to make a wireless connection for the first time Before you start the pairing operation make sure...

Страница 8: ...s network list return to the app and push the Yes button on the initial WiFi screen BASCOGATEWAY XXXXX 7 You will prompted to enter the network SSID and Password both are case sensitive The mobile dev...

Страница 9: ...al voltage of the appliance 14 Push the save button to save your changes 15 After pairing multiple modules the app screen will be similar to the image below 16 To arrange priorities push the rearrange...

Страница 10: ...equired to read and comply with the InfoHub Subscription Service Agreement prior to activation of the monthly subscription and the Terms of Use and Privacy Policy prior to accessing the InfoHub portal...

Страница 11: ...11 This page was intentionally left blank...

Страница 12: ...12 BRIGGSandSTRATTON COM This page was intentionally left blank...

Страница 13: ...Instrucciones de instalaci n y operaci n Preguntas La ayuda est muy cerca Llame a nuestra l nea de ayuda 800 732 2989 De lunes a viernes entre las 8 00 a m y las 5 00 p m hora del centro Copyright Br...

Страница 14: ...ratton No exponga el equipo a un ambiente con exceso de humedad polvo suciedad o vapores corrosivos Permanezca alerta en todo momento mientras trabaja en el equipo Nunca trabaje en los equipos cuando...

Страница 15: ...ia Este dispositivo cumple con los l mites de exposici n como se muestra en un an lisis de exposici n a la radiofrecuencia El dispositivo debe instalarse de tal forma que se mantenga una distancia m n...

Страница 16: ...es de campo K Puerto de servicio en serie El m dulo inal mbrico puede instalarse donde resulte pr ctico y haya una buena se al inal mbrica tanto en una ubicaci n en interiores como en exteriores Se de...

Страница 17: ...z LED de falla L Luz LED de la red A Entrada de potencia de 24 V CA B Bot n de configuraci n de red unirse C Salida de carga n 2 D Salida de carga n 1 E Luz LED de falla F Luz LED de la red G Luz LED...

Страница 18: ...r en la posici n de apagado 3 Retire el fusible del generador principal 4 El panel de control del generador recibe tensi n del suministro el ctrico de la red p blica Desconecte la energ a el ctrica an...

Страница 19: ...rico y el sistema de administraci n de potencia Amplify para permitir una conexi n inal mbrica Debe emparejar los dispositivos para poder realizar una conexi n inal mbrica por primera vez Antes de ini...

Страница 20: ...ATEWAY XXXXX 7 Se le solicitar que ingrese el identificador de conjunto de servicio Service Set Identifier SSID y la contrase a de la red ambos distinguen entre may sculas y min sculas El dispositivo...

Страница 21: ...spositivo 14 Pulse el bot n Guardar para guardar los cambios 15 Despu s de emparejar varios m dulos la pantalla de la aplicaci n ser similar a la imagen a continuaci n 16 Para organizar las prioridade...

Страница 22: ...leer y cumplir con el Contrato de servicio de suscripci n de InfoHub antes de activar la suscripci n mensual y los T rminos de uso y la Pol tica de privacidad antes del acceder al portal InfoHub Visi...

Страница 23: ...11 Esta p gina se dej intencionalmente en blanco...

Страница 24: ...12 BRIGGSandSTRATTON COM Esta p gina se dej intencionalmente en blanco...

Страница 25: ...ion Amplify Instructions d installation et d op ration Des questions De l aide au bout des doigts Appeler notre service de d pannage 800 732 2989 Du lundi au vendredi de 8 h 17 h heure du Centre Copyr...

Страница 26: ...ssive la poussi re la salet ou aux vapeurs corrosives Demeurer alerte en tout temps lorsque vous travaillez sur cet quipement Ne jamais travailler sur l quipement si vous tes fatigu physiquement ou me...

Страница 27: ...eil satisfait aux limites d exposition indiqu es dans une analyse d exposition aux rayonnements RF Cet appareil doit tre install de sorte qu il y ait en tout temps une distance de 20 cm entre l appare...

Страница 28: ...ntr e raccords sur place K Port de service en s rie Le module sans fil peut tre install n importe quel endroit pratique avec un bon signal sans fil l int rieur ou l ext rieur Le module de passerelle s...

Страница 29: ...elais K DEL de d faillance L DEL de r seau A Entr e d alimentation de 24 V c a B Bouton de configuration du r seau Joindre C Sortie de charge n 2 D Sortie de charge n 1 E DEL de d faillance F DEL de r...

Страница 30: ...r principal de la g n ratrice la position ARR T 3 Retirer le fusible de la g n ratrice principale 4 De la tension de service est pr sente au tableau de commande de la g n ratrice Retirer les fusibles...

Страница 31: ...e sans fil et le syst me de gestion de l alimentation Amplify pour permettre la connexion sans fil Vous devez jumeler les appareils pour pouvoir tablir une connexion sans fil la premi re fois Avant d...

Страница 32: ...x de votre appareil mobile revenir l application et appuyer sur le bouton Oui sur l cran Wi Fi initial BASCOGATEWAY XXXXX 7 Vous devrez entrer le SSID et le mot de passe du r seau les deux sont sensib...

Страница 33: ...l 14 Appuyer sur le bouton pour enregistrer vos changements 15 Apr s avoir jumel des modules multiples l cran de l application ressemblera ce qui suit 16 Pour r am nager les priorit s appuyer sur le b...

Страница 34: ...avant l activation de l abonnement mensuel ainsi que les conditions g n rales d utilisation et la politique de confidentialit avant l acc s au portail InfoHub Veuillez visiter le www briggsinfohub com...

Страница 35: ...11 Cette page a t laiss e en blanc intentionnellement...

Страница 36: ...12 BRIGGSandSTRATTON COM Cette page a t laiss e en blanc intentionnellement...

Отзывы: