64
13.3 Sub-Stream Recording Parameters
The following table is valid for both the MDR-404xx-500 using all 4 channels and MDR-408xx-1000 using all 8 channels. It illustrates
approximate SD recording times in hours at CIF resolution and different frame rates. Ranges of frame rates are controlled by the sub-stream
bandwidth. Refer to section 4.1.5 Sub-Stream Settings.
Bandwidth
4096 Kbps
3200 Kbps
1500 Kbps
500 Kbps
Recording Time
onto SD (hours)
depending on
frame rate
25 fps (fastest)
12
24 fps
12
23 fps
13
22 fps
14
21 fps
14
20 fps
15
19 fps
15
18 fps
16
17 fps
16
16 fps
17
15 fps
20
14 fps
21
13 fps
23
12 fps
25
11 fps
27
10 fps
29
9 fps
31
8 fps
37
7 fps
43
6 fps
50
5 fps
60
4 fps
75
3 fps
101
2 fps
152
1 fps (slowest)
305
13.4 User Log Description
Reason
Log Description
Example
Description
MDR boot up
record the time of MDR boot up
09:24:03 01 poweron;
MDR powers on
MDR power off
record the shut down time
poweroff
SignalHander(signal:XX)(pid:YY);
MDR powered off by accident. Record
signal XX, thread ID YY.
poweroff timer;
MDR Powered off by scheduled timer
poweroff key;
MDR Powered off due to vehicle ignition
off
poweroff tork;
MDR Powered off because off time up or
vehicle key pulled out
poweroff remote;
MDR Powered off by remote control
poweroff hddkey;
MDR Powered off by MCU key
poweroff hdd error;
MDR Powered off by HDD error
poweroff upgrade;
MDR Powered off because of system
upgrade
poweroff modify para;
System parameters have been changed
poweroff format;
Reboot after formatting
poweroff low voltage;
MDR Powered off because of low
voltage
video loss
record video loss information
1.vloss channel 1 vloss;
Record how many channels lost video
It is considered power cut off
when the voltage value falls
under 7V.
2.vloss electricity was cut off;
MDR Powers off when circuit protection
kicks in
3.vloss electricity was cut off stop
record fail;
Power is cut off, and MDR processing
video.
4.vloss power was supply;
Voltage was pulled up to normal level
and MDR stops using internal
capacitance.
start to record
Logs when and which channel
start recording. These are main
record and mirror record.
1.s-record ch1;
Channel 1 starts to record.
2.s-record mirror ch1;
Channel 1 starts to record mirror
recording.
3.s-record ch1 RCT_STARTING;
Starting to record (this kind of log record
sometimes does not get stored).
record stop
Logs when and which channel
stop recording. These are main
record and mirror record.
1.e-record ch1;
Channel 1 stopped recording.
2.e-record stop mirror ch1 over;
Channel 1 stopped mirror recording.
3.e-record stop ch1 over type:1;
Channel 1 stopped recording because
the system parameters were changed.
3.e-record stop ch1 over type:2;
Channel 1 stopped recording because
the system time is changed.
3.e-record stop ch1 over type:3;
Channel 1 stopped recording because
the system was upgraded.
3.e-record stop ch1 over type:4;
Channel 1 stopped recording because
the HDD has been formatted.
3.e-record stop ch1 over type:5;
Channel 1 stopped recording because
HDD has not recovered by the end of
the video recording.