22
New Year’s Timer
Operation:
The timer will display real time hrs:min:sec
On 12/31/2005 at 22:59:59, the display will switch from real time to down timer mode. The
down timer will start at 1:00:00 and countdown to 00:00:00. At 00:00:10, the display will blink
during the last ten seconds. When the timer stops at 00:00:00, the display will change to display
the year (2016). To return the display to real time, cycle power to the display. The alarm relay
will close for 1 second if installed.
To test the display, set the date to 12/31/2016. Then set Modes 7=0:00, 8=20, 27-1=23:59 and
28-1=40. Exit the menu system and run the real time forward to 11:59 PM. The display will
switch from real time to countdown timer at 11:59:40 PM and countdown starting at 00:00:20.
At 00:00:10 the display will blink until it stops at 00:00:00. At this time, the display will switch
to 2006.
To restore from test mode, cycle power to the display. Then set Modes 7=1:00, 8=0, 28-1=59.
Or restore the original display configuration by restoring customer defaults.
The following configuration can also be used with four digital displays by changing the display
types to: 20-1=2 and 36-1=54.
Modes:
5=1
7=1:00
9=0:00
13=1
20-1=46 (change for other display types)
20-2=48 (change for other display types)
27-1=22:59
28-1=59
29-1=8
30-1=0
32-4=2
32-5=1
32-13=5
32-37=1
32-45=71
34-1=99
36-1=46 (change for other display types)
36-2=48 (change for other display types)
37-1=0
37-8=1
43-1=3
43-3=10
43-4=10
43-5=5
44-1=12/31 - ending month and day
44-2=2016 - ending year