First Menu
Level
Mode Number
Second
Menu
Level
Value
Range
Mode Description and Instructions
date range. There are 20 date ranges available. The Mode 38 function has changed.
It now determines which schedule is active for date ranges defined in Modes 53, 54,
55 and 56. Setting Mode 32-4=4 allows the Timer control button to switch between
schedules 0-10 (0 activates date range switching). Press Timer Control to access
Mode 37-1. Use the Up and Down buttons to change the schedule from 0-10, then
press Timer Control to save and exit.
37
2
0-2
Manual Alarm Button
This Mode applies to the master clock relay only. When this Mode is enabled, alarm
schedule switching using the Timer Control (TC) button is disabled.
0=not active (default),
1=code blue line toggles alert horn on and off. Mode 45-19 optionally determines the
number of seconds the alarm will sound before automatically turning off. If the
timeout value is 0, the alarm will sound until the code blue line is momentarily
closed.
This setting will also cause the timer control button to act as a snooze button, turning
off the alarm before the alarm period has expired.
2=alert horn will sound as long as code blue line is closed. The Panic Alarm function
overrides all other timer control functions. This mode may used with real time alarms
to turn off the alarm before the predefined alarm duration expires.
37
3
0,9
58
th
/59
th
Minute Transmit
0=disabled (default)
9=enabled
When 58
th
/59
th
minute sync transmit is enabled, the internal relay will be used to send
sync pulses to secondary clocks. When enabled, the internal relay is no longer used
as an alarm relay. Wireless alarm relays must be used. When 59
th
/59
th
minute sync is
disabled, the internal relay can be used for alarms.
37
10
0-18
Analog Clock Time Zone Position Number
0 = disabled
1-18 = enabled
This mode is used to configure the zone position number of analog clocks used in a
time zone display. This number is the sequence of available clock zones. It is not the
offset from UTC. More than one clock may use the same zone number if the offset
from UTC are to be the same. Set Mode 37-10 to the desired zone number 1-18. The
master clock will then begin broadcasting on this zone, plus flag instructing the
analog clock to save the zone number. Once the master clock is broadcasting the
time zone command, remove and reinsert the analog clock’s batteries. The hands will
begin to move. Once they stop, set mode 27-10 back to 0. To configure another
clock, repeat the process.
The zone position number will appear in the upper right corner of the master clock
while the time zone position command is active.
This feature is available in RC100TZ version 4.87 and later.
37
28
0,1
Enable/Disable Analog Time Zone Master Clock