44
First Menu
Level
Mode Number
Second
Menu
Level
Value
Range
Mode Description and Instructions
This special diagnostic mode is for factory use only. This mode is used to reset the
software without removing power from the display.
50
5
Restore-User Default Configuration
This mode may be used to retrieve the custom configuration from memory if it was
previously stored using mode 50-6. To execute the configuration retrieval process,
press the mode button while 50-5 is displayed. The clock will resume normal
operation after the configuration is retrieved.
50
6
1-3
Save-User Default Configuration
This mode is used to store a custom configuration. Use mode 50-5 to restore the
configuration. To execute the configuration save process, press the mode button
while 50-6 is displayed. The clock will resume normal operation after the
configuration is saved.
52
1
1-365
Custom Daylight Time Switch -User Defined 10
Enter the day of the year to switch from standard time to daylight time. Both modes
52-1 and 52-2 must be set to the desired day of the year. See also Mode 45-20 to
define new daylight saving rule.
Mode 45-20 must be set to 0 to enable this mode;
otherwise, use Mode 45-20 to enable rule base switching.
For U.S. Spring switch to Daylight Saving Time: 2010=73, 2011=72, 2012=71,
2013=69,2014=68, 2015=67, 2016=73, 2017=71
52
2
1-365
Custom Julian Standard Time Switch -User Defined 10
Enter the day of the year to switch from daylight time to standard time. Both modes
52-1 and 52-2 must be set to the desired day of the year. See also Mode 45-21 to
define new daylight saving rule.
Mode 45-21 must be set to 0 to enable this mode;
otherwise, use Mode 45-21 to enable rule base switching.
For U.S. Fall switch to Standard Time: 2010=311, 2011=310, 2012=309,
2013=307,2014=306, 2015=305, 2016=311, 2017=309
53
1-20
01/01
to
12/31
Alarm Schedule Date Range - Beginning Month/Day
12/31 (default) - Set Mode 37-1=0 to enable. This mode is used to set the beginning
month and day of an alarm date range. If Mode 54 has the same date, the alarm will
activate only one day. If the Year in Mode 55 equals 2000, then the alarm will
activate every year with the month/day range specified. The ending date must be
occur after the beginning date. See also Mode 38 to force an alarm schedule active.
Alarm group 1 is different than the other 19 alarm groups. If no date range is active,