background image

Thank you for purchasing the Breckwell Pellet Burning Stove. You are now prepared to burn 

wood in the most efficient, convenient way possible. To achieve the safest, most efficient and 

most enjoyable performance from your stove, you must do three things: 1) Install it properly; 

2) Operate it correctly; and 3) Maintain it regularly. The purpose of this manual is to help you 

do all three.  

 

PLEASE read this entire manual before installation and use of this pellet fuel-burning 
room heater. Failure to follow these instructions could result in property damage, 
bodily injury or even death. 
 
Keep this manual handy for future reference. 

 

Your Breckwell P24 comes as a fireplace insert or as a freestanding stove with a pedestal. 

 

This stove has been independently tested to ASTM E1509-95 Standard Specification for 

Room Heaters, Pellet Fuel Burning Type 1, UL 1482-1998 Standard for Solid Fuel Room 

Heaters, Oregon Administrative Rules for Mobile Homes (814-23-900 through 814-23-909) 

and Installation as a Stove Heater. 

 

This pellet stove, when installed, must be electrically grounded in accordance with local 

codes, or in the absence of local codes, with the 

National Electrical Code, ANSI/NFPA 70

 

This appliance is designed specifically for use only with pelletized wood. It is designed for 

residential installation according to current national and local building codes as a freestanding 

room heater. It is also approved as a mobile home heater which is designed for connection to 

an outside combustion air source. 

 

The stove will not operate using natural draft or without a power source for the blower 

systems and fuel feed system and must not be burned with any type of coal (see 

PROPER 

FUEL

). 

 

This stove is designed to provide the optimum proportions of fuel and air to the fire in order to 

burn free of smoke and soot. Any blockage of the air supply to or from the stove will seriously 

degrade its performance and will be evidenced by a smoking exhaust and a sooting window. 

For best operation the ash content of the pellet fuel should be less than 1% and the calorific 

value approximately 8200 BTU/LB. Avoid high ash content fuels because this will rapidly fill 

up the burn pot and eventually cut off the combustion air supply. 

 

Commercial and industrial installations of Breckwell Pellet Stoves should not be used since 

operational control is often not well managed in these settings.

 

 

 

 

 

 

 

 

 

 

INTRODUCTION 

IMPORTANT INFORMATION 

 

Model: _____P24___________________ 

Style: ____________________________ 

Serial Number:_____________________ 

Purchase Date: ____________________ 

Purchased From:___________________ 

 

 

      ___________________ 

 

 

      ___________________ 

MAIL YOUR WARRANTY CARD TODAY 

To receive full warranty coverage, you will 

need to show evidence of the date you 

purchased your stove. We suggest that 

you attach your sales invoice to this page, 

and fill in the form on the left, so that you 

will have all the information you need in 

one place should the need for service or 

information occur. 

www.PelletKing.com

Содержание Tradition P24FS

Страница 1: ...he installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area PLEASE read this entire manual before installation and use...

Страница 2: ...o approved as a mobile home heater which is designed for connection to an outside combustion air source The stove will not operate using natural draft or without a power source for the blower systems...

Страница 3: ...possible this can cause the temperature of the stove to rise to operational levels one of the sensors could then make the stove start on its own It is recommended that the stove be unplugged when not...

Страница 4: ...Starting a Warm Stove 16 If Stove Runs Out Of Pellets 17 Damper Control 17 Refueling 17 Breckwell Maintenance Tool 17 Shutdown Procedure 17 Safety Features 17 Optional Thermostat 18 Thermostat Install...

Страница 5: ...lation in residential mobile home and alcove applications The P24 Insert is approved for installation into code complying masonry fireplaces The P24 Insert is also approved for use in listed factory b...

Страница 6: ...stion air is easily available to the air inlet A closeable outside air register can be used in tightly insulated homes In insert installations flashing vents should not be restricted The flashing shou...

Страница 7: ...ve exhaust vent refer to figure 5 3 Always maintain 3 clearance from combustible materials 4 Install L Vent wall thimble per L Vent manufacturer s instructions 5 Attach enough piping to penetrate and...

Страница 8: ...L Vent manufacturer s instructions 1 Always maintain 3 clearance from combustible materials When passing through additional floors or ceilings always install firestop spacer 2 After lining up for hole...

Страница 9: ...from 3 L Vent to 6 or 8 Class A chimney Figure 10a As an alternative 3 or 4 L Vent can be run inside existing chimney to termination Figure 10b This is the preferred method Follow guidelines for equiv...

Страница 10: ...ances in Figures 1 2 Mark the center of the hole where the pipe is to pierce the masonry chimney 2 It will be necessary to break out the masonry around the location of the pipe center mark Use a 4 inc...

Страница 11: ...gest painting the interior of particularly old and dirty fireplaces to seal any odors In zero clearance fireplace installations when the fireplace opening is above the floor or raised hearth the adjus...

Страница 12: ...onry Fireplaces Only Refer to Figure 15 1 You will need a pipe length that extends 12 above the blanking plate NOTE This installation is optional but not recommended Outside combustion air cannot be d...

Страница 13: ...t sides and rear of the stove in fireplace must be enclosed per the applicable electrical standards NOTE Floor protection for Built in raised hearths requires a continuous sheet beneath to prevent the...

Страница 14: ...the chimney flue A permanent metal warning label must be attached to the back wall of the fireplace opening stating the following This fireplace has been altered to accommodate a fireplace insert and...

Страница 15: ...on the Heat Level Advance setting d RESET TRIM Different size and quality pellet fuel and installation altitude may require adjustment of the 1 feed setting on the Heat Level Advance bar graph This is...

Страница 16: ...ckwell approved burnpot NOTE During the first few fires your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this A...

Страница 17: ...r tubes see instructions in CLEANING c Scrape ashes from burnpot SHUTDOWN PROCEDURE Turning your Breckwell stove off is a matter of pressing the On Off control panel switch The green light will go out...

Страница 18: ...his owner s manual HIGH LOW THERMOSTAT MODE When engaged in this mode the stove will automatically switch between two settings When warm enough it will switch to the 1 or low setting The room air blow...

Страница 19: ...the control panel g KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES SUCH AS FURNITURE DRAPES TOYS ETC AT LEAST THREE FEET FROM THE OPERATING STOVE h Maintain proper ventilation It is important that...

Страница 20: ...r vacuum to remove ashes WARNING Make sure ashes are cool to the touch before using a vacuum See VACUUM USE f Periodically remove and empty ash bin see Figure 24 by unscrewing the two knobs on the fro...

Страница 21: ...is highly combustible INSPECT BEHIND THESE CLEANING PLATES AT LEAST ONCE PER TON OF PELLETS BURNED UNTIL YOU ARE FAMILIAR WITH HOW ASHES AND CREOSOTE ACCUMULATE WITH YOUR OPERATING PRACTICES Use the...

Страница 22: ...his service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repaired To clean the chimney detach the vent at the combustio...

Страница 23: ...MAINTENANCE 23 FIGURE 29 www PelletKing com...

Страница 24: ...ot make sure the slider plate is in place to seal off the firebox floor 4 Vent pipe is incorrectly installed Check to make sure vent pipe installation meets criteria in owner s manual 5 The airflow sw...

Страница 25: ...r tube for signs of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam 7 The auger motor has failed Remove the auger motor from the auger shaft and try to run...

Страница 26: ...ck the voltage going to the igniter during startup It should be a full current If the voltage is lower than full current check the wiring If the wiring checks out good the board is bad SMOKE SMELL COM...

Страница 27: ...ger shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing Next re...

Страница 28: ...each setting after the stove has completed the startup cycle Make sure the times match the auger timing chart If the auger motor runs constantly the board is bad 8 Combustion blower is not spinning f...

Страница 29: ...nd what setting No other types of fuel have been approved for Breckwell pellet stoves If there are signs of other types of fuel being used advise the consumer to stop using them immediately 4 Power su...

Страница 30: ...FIGURE 30 ELECTRICAL DIAGRAM 30 www PelletKing com...

Страница 31: ...rol Panel C E 401 Combustion Blower A E 027 Convection Blower A E 033 Door Gasket C G 050 Door Glass C D 030 Exhaust Adapter 3 C M 020 Exhaust Adapter 4 A 4 VA Hot Rod Igniter C E IGN Thermodisk Proof...

Страница 32: ...umstances beyond Breckwell s control If warranty service is needed during the warranty period notify the nearest Authorized Breckwell Dealer Provide your name address phone number serial number and mo...