background image

E. 

INSTALLATION IN TO A FACTORY BUILT 
(METAL) FIREPLACE

 

        

(Refer to figure 18) 

 

When installing into a factory built fireplace, the firebox 

must accept the insert without modification other than 

removing bolted or screwed together pieces such as 

smoke shelf/deflectors, ash lips, screen or door tracks 

and damper assemblies. These items must be reinstalled 

to restore the fireplace to its original operating condition if 

the insert is removed and not replaced. The removal of 

any part must not alter the integrity of the listed fireplace 

in any way. In zero-clearance fireplace installations, when 

the fireplace opening is above the floor or raised hearth, 

the adjustable “Breckwell P24 Z-C skirt” (part # A-ZC-

SKRT), or “Breckwell P24 Z-C Legs” (part #A-S-

ZCLEGS), can be used to bridge the gap between the 

hearth and stove bottom.  

(Refer to figure 13) 

 

The factory built fireplace must be listed per UL 127. 

Installation must include a full height listed chimney liner 

meeting type HT requirements (2100

°

 F) per 1777 (U.S.). 

The liner must be securely attached to the insert flue 

collar and the chimney top. The damper area must be 

sealed to prevent room air passage to chimney cavity.  

 

Alteration of the fireplace in any manner is not permitted 

except with the following exceptions: 

  External trim pieces, which do not affect the 

operation of the fireplace, may be removed proving 

they can be stored on or within, the fireplace for re-

assembly if the insert is removed. 

  The fireplace damper may be removed to install the 

chimney liner. 

Circulating air chambers, louvers or cooling air inlet or 

outlet ports (i.e. in a steel fireplace liner or metal heat 

circulator) shall not be blocked. 

Means must be provided for removal of the insert to clean 

the chimney flue. 

A permanent metal warning label must be attached to the 

back wall of the fireplace opening stating the following: 

  “This fireplace has been altered to accommodate a 

fireplace insert and should be inspected by a 

qualified person prior to re-use as a conventional 

fireplace.” 

  This label is available upon request. 

 
Final approval is contingent on the authority having 
jurisdiction. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 

 

ELECTRICAL INSTALLATION 

 

This stove is provided with a 6-foot grounded electrical cord 

extending from the rear of the stove. We recommend 

connecting to a good quality surge protector that is plugged 

into a standard three-prong, 120V, 60 Hz electrical outlet. 

Voltage variations can lead to serious performance 

problems. The Breckwell electrical system is designed for 

120V AC with no more than 5% variation. Breckwell cannot 

accept responsibility for poor performance or damage due to 

inadequate voltage. If connected to an older, two-prong 

outlet, a separate ground wire should be run to a proper 

ground (refer this to a qualified technician). Always route the 

electrical cord so that it will not come in contact with any hot 

part of the stove. 

 

 

SPECIAL MOBILE HOME REQUIREMENTS 

 

WARNING: DO NOT INSTALL IN A SLEEPING ROOM.

 

 

For installation in a mobile home, an outside source of combustion air must 

be used (see “

COMBUSTION AIR SUPPLY”

). 

 

The P24 must be grounded to the steel chassis of the home with 8 Ga. 

copper wire using a serrated or star washer to penetrate paint or protective 

coating to ensure grounding. 

 

The P24 must be securely fastened to the floor of the mobile home through 

the two holes in the rear of the stove using two ¼” lag bolts that are long 

enough to go through both a hearth pad, if used, and the floor of the home.  

 

 

Refer to “

VENTING

” for proper exhaust configurations. 

 

CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME 
FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED. 

FIGURE 18 

INSTALLATION 

14 

www.PelletKing.com

Содержание Tradition P24FS

Страница 1: ...he installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area PLEASE read this entire manual before installation and use...

Страница 2: ...o approved as a mobile home heater which is designed for connection to an outside combustion air source The stove will not operate using natural draft or without a power source for the blower systems...

Страница 3: ...possible this can cause the temperature of the stove to rise to operational levels one of the sensors could then make the stove start on its own It is recommended that the stove be unplugged when not...

Страница 4: ...Starting a Warm Stove 16 If Stove Runs Out Of Pellets 17 Damper Control 17 Refueling 17 Breckwell Maintenance Tool 17 Shutdown Procedure 17 Safety Features 17 Optional Thermostat 18 Thermostat Install...

Страница 5: ...lation in residential mobile home and alcove applications The P24 Insert is approved for installation into code complying masonry fireplaces The P24 Insert is also approved for use in listed factory b...

Страница 6: ...stion air is easily available to the air inlet A closeable outside air register can be used in tightly insulated homes In insert installations flashing vents should not be restricted The flashing shou...

Страница 7: ...ve exhaust vent refer to figure 5 3 Always maintain 3 clearance from combustible materials 4 Install L Vent wall thimble per L Vent manufacturer s instructions 5 Attach enough piping to penetrate and...

Страница 8: ...L Vent manufacturer s instructions 1 Always maintain 3 clearance from combustible materials When passing through additional floors or ceilings always install firestop spacer 2 After lining up for hole...

Страница 9: ...from 3 L Vent to 6 or 8 Class A chimney Figure 10a As an alternative 3 or 4 L Vent can be run inside existing chimney to termination Figure 10b This is the preferred method Follow guidelines for equiv...

Страница 10: ...ances in Figures 1 2 Mark the center of the hole where the pipe is to pierce the masonry chimney 2 It will be necessary to break out the masonry around the location of the pipe center mark Use a 4 inc...

Страница 11: ...gest painting the interior of particularly old and dirty fireplaces to seal any odors In zero clearance fireplace installations when the fireplace opening is above the floor or raised hearth the adjus...

Страница 12: ...onry Fireplaces Only Refer to Figure 15 1 You will need a pipe length that extends 12 above the blanking plate NOTE This installation is optional but not recommended Outside combustion air cannot be d...

Страница 13: ...t sides and rear of the stove in fireplace must be enclosed per the applicable electrical standards NOTE Floor protection for Built in raised hearths requires a continuous sheet beneath to prevent the...

Страница 14: ...the chimney flue A permanent metal warning label must be attached to the back wall of the fireplace opening stating the following This fireplace has been altered to accommodate a fireplace insert and...

Страница 15: ...on the Heat Level Advance setting d RESET TRIM Different size and quality pellet fuel and installation altitude may require adjustment of the 1 feed setting on the Heat Level Advance bar graph This is...

Страница 16: ...ckwell approved burnpot NOTE During the first few fires your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this A...

Страница 17: ...r tubes see instructions in CLEANING c Scrape ashes from burnpot SHUTDOWN PROCEDURE Turning your Breckwell stove off is a matter of pressing the On Off control panel switch The green light will go out...

Страница 18: ...his owner s manual HIGH LOW THERMOSTAT MODE When engaged in this mode the stove will automatically switch between two settings When warm enough it will switch to the 1 or low setting The room air blow...

Страница 19: ...the control panel g KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES SUCH AS FURNITURE DRAPES TOYS ETC AT LEAST THREE FEET FROM THE OPERATING STOVE h Maintain proper ventilation It is important that...

Страница 20: ...r vacuum to remove ashes WARNING Make sure ashes are cool to the touch before using a vacuum See VACUUM USE f Periodically remove and empty ash bin see Figure 24 by unscrewing the two knobs on the fro...

Страница 21: ...is highly combustible INSPECT BEHIND THESE CLEANING PLATES AT LEAST ONCE PER TON OF PELLETS BURNED UNTIL YOU ARE FAMILIAR WITH HOW ASHES AND CREOSOTE ACCUMULATE WITH YOUR OPERATING PRACTICES Use the...

Страница 22: ...his service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repaired To clean the chimney detach the vent at the combustio...

Страница 23: ...MAINTENANCE 23 FIGURE 29 www PelletKing com...

Страница 24: ...ot make sure the slider plate is in place to seal off the firebox floor 4 Vent pipe is incorrectly installed Check to make sure vent pipe installation meets criteria in owner s manual 5 The airflow sw...

Страница 25: ...r tube for signs of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam 7 The auger motor has failed Remove the auger motor from the auger shaft and try to run...

Страница 26: ...ck the voltage going to the igniter during startup It should be a full current If the voltage is lower than full current check the wiring If the wiring checks out good the board is bad SMOKE SMELL COM...

Страница 27: ...ger shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing Next re...

Страница 28: ...each setting after the stove has completed the startup cycle Make sure the times match the auger timing chart If the auger motor runs constantly the board is bad 8 Combustion blower is not spinning f...

Страница 29: ...nd what setting No other types of fuel have been approved for Breckwell pellet stoves If there are signs of other types of fuel being used advise the consumer to stop using them immediately 4 Power su...

Страница 30: ...FIGURE 30 ELECTRICAL DIAGRAM 30 www PelletKing com...

Страница 31: ...rol Panel C E 401 Combustion Blower A E 027 Convection Blower A E 033 Door Gasket C G 050 Door Glass C D 030 Exhaust Adapter 3 C M 020 Exhaust Adapter 4 A 4 VA Hot Rod Igniter C E IGN Thermodisk Proof...

Страница 32: ...umstances beyond Breckwell s control If warranty service is needed during the warranty period notify the nearest Authorized Breckwell Dealer Provide your name address phone number serial number and mo...

Отзывы: