     INSTALLATION

4.1 POSITIONING THE STOVE

It is very important to position the stove as close as possible to the chimney, and in an area that will favor the most ef

fi

 cient heat 

distribution possible throughout the house.  The stove must therefore be installed in the room where the most time is spent, and in 
the most spacious room possible.  Recall that stoves produce radiating heat, the heat we feel when we are close to a stove. A stove 
also functions by convection, that is through the displacement of hot air accelerated upwards and its replacement with cooler air. If 
necessary, the hot air distribution from the stove may be facilitated by the use of a fan or blower.

•  Do not place any combustible material within 4’ (1.2m) of 

the front of the unit.

•  The clearance between the 

fl

 ue pipe and a wall are valid only 

for vertical walls and for vertical 

fl

 ue pipe.

•  The chimney connector must not pass through an attic or roof 

space, closet or similar concealed space, a 

fl

 oor, or a ceiling.

•  For Canadian installations, where passage through a wall, 

or partition of combustible construction is desired, the 
installation must conform to CAN/CSA-B365.

• A 

fl

 ue pipe crossing a combustible wall must have a minimum 

clearance of 18” (457.2mm).

• To reduce 

fl

 ue clearances from combustible materials, contact 

your local safety department.

Back wall / Arrière Mur

Side wall / P

a

roi Lat

é

rale

Side wall / P

a

roi Lat

é

rale

Sd

e

a

/

a

o

at

éa

e

E

E

D

D

Back wall / Arrièr

e Mur

Ceiling / Plafond

Floor Protector / Protection de Plancher

g

F

G

Back wall / Arrière Mur

Side wall / P

a

roi Lat

é

rale

Side wall / P

a

roi Lat

é

rale

Sd

e

a

/

a

o

a

ae

C

B

A

Dimension

Inch

mm

A

Backwall to Stove

11

280

B

Sidewall to Stove

7

178

C

Sidewall to Flue

17.3

440

D

Wall to Stove (Angled Installation)

3

77

E

Wall to Flue (Angled Installation)

14.4

366

F

Ceiling Height

84

2134

G

Backwall to Flue

14.8

376

4.2 FREE STANDING STOVE INSTALLATION

A stove must never be installed in a hallway or near a staircase, since it may block the way in case of 

fi

 re or fail to respect required 

clearances. It is of the utmost importance that the clearances to combustible materials be strictly adhered to during installation of the 
stove.  Refer to the table and diagrams below for minimum required clearances.

SAFETY NOTICE

 

IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO  REDUCE THE RISK OF 
FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. 

 

CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT PERMITS, 
RESTRICTIONS AND INSTALLATIONS REQUIREMENTS IN YOUR AREA.

 

USE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED.

 

SMOKE EXPELLED FROM THE UNIT, BY EITHER PAINT CURING, OPENING THE FUEL LOADING DOOR, 
OR A NEGATIVE PRESSURE INSIDE THE HOME, COULD TRIGGER THE SMOKE DETECTORS. MOUNT 
SMOKE DETECTORS AT LEAST 10’ FROM STOVE

 

NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, 
OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER. KEEP  ALL SUCH LIQUIDS 
WELL AWAY FROM THE HEATER WHILE IT IS IN USE.

 

IN THE EVENT OF A CHIMNEY FIRE, PUSH THE AIR CONTROL FULL CLOSED TO  DEPRIVE THE FIRE OF 
OXYGEN. CALL THE FIRE DEPARTMENT.

 

A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED.

 

ROOM HEATER, SOLID FUEL TYPE, ALSO FOR USE IN MOBILE HOMES.

Содержание SWC21

Страница 1: ...Installation Could Void Your Warranty SAVE THESE INSTRUCTIONS THIS MANUALWILL HELPYOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A S...

Страница 2: ...cm Flue Pipe Type Standard Single Wall or Double Wall Black or Blued Steel 2100 F 650 C Minimum Chimney Height 12 3 7m Maximum Log Length 18 457mm Electrical 115V 60Hz 1 5A Dimensions Overall without...

Страница 3: ...remove the baffle board 2 2 TOOLS AND MATERIALS NEEDED FOR INSTALLATION A 7 16 socket wrench A 5 16 socket Best if using a power drill and a socket bit A pair of pliers or channel locks A power drill...

Страница 4: ...and pedestal to the appliance The safest method is to roll the appliance on its back When using this method you should first remove the firebrick from the unit so as to reduce weight and possible brea...

Страница 5: ...r Side wall Paroi Lat rale Side wall Paroi Lat rale S de a a o at a e C B A Dimension Inch mm A Backwall to Stove 11 280 B Sidewall to Stove 7 178 C Sidewall to Flue 17 3 440 D Wall to Stove Angled In...

Страница 6: ...s solid surface to protect against infiltration of live embers and ash The stove must be placed on solid concrete solid masonry or when installed on a combustible floor on a Type 2 floor protector lis...

Страница 7: ...he floor 2 To attach the leg model use two 3 8 16 UNC bolts through the floor The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire using a serrated or...

Страница 8: ...ng a window slightly on a calm windless day alleviates any of the above symptoms 4 The house is equipped with a well sealed vapor barrier and tight fitting windows and or has any powered devices that...

Страница 9: ...ft effect your stove s performance is directly dependent on an adequate draft from your chimney Do not connect this unit to a chimney flue serving another appliance The following recommendations may b...

Страница 10: ...y a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove t...

Страница 11: ...nector and a minimum 24 gauge ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fibergla...

Страница 12: ...with the upper end of the section toward the chimney Any installation with a horizontal run of stove pipe must conform to NFPA 211 You may contact NFPA National Fire Protection Association and request...

Страница 13: ...same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance t...

Страница 14: ...lackened windows Incomplete log combustion Smaller pieces of wood will dry faster All logs exceeding 6 in diameter should be split The wood should not be stored directly on the ground Air should circu...

Страница 15: ...ntrolled combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for each given situation The wood will burn slowly if the wood sto...

Страница 16: ...t should be removed to reduce the risk of a chimney fire We strongly recommend that you install a magnetic thermometer on your smoke exhaust pipe approximately 18 above the stove This thermometer will...

Страница 17: ...hed only when cold 7 2 GASKETING It is recommended that you change the door gasket which makes your stove door air tight once a year in order to insure good control over the combustion maximum efficie...

Страница 18: ...Possible Remedies Unplug blower first if equipped Cool exhaust flue gasses Use double or triple wall external chimney Burning unseasoned wet wood Use dry seasoned hardwood Smoke rolls out when feed o...

Страница 19: ...1 11 86668 Damper Rod 1 12 83614 15 Threaded Rod 4 13 88147 Baffle Board 1 14 40619 Top Cast Grate Left 1 15 40620 Top Cast Grate With Flue 1 16 40621 Top Cast Grate Right 1 17 892342 Door Glass 1 Whe...

Страница 20: ...20 2 6 5 5 10 11 9 8 1 17 14 4 3 3 7 13 15 16 12...

Страница 21: ...21 NOTES...

Страница 22: ...the nameplate attached to the stove When ordering repair parts always give the following information as shown in this list 10 0 HOW TO ORDER REPAIR PARTS 1 The part number SWC21 2 The part description...

Страница 23: ...______ Reason for Purchase Alternative Heat Main Heat Source Decoration Cost Other _________________________ What was the determining factor for purchasing your new appliance _______ I have read the o...

Страница 24: ...24 CUT HERE CUT HERE Fold Here Fold Here Fold Here PLACE STAMP HERE Breckwell 227 Industrial Park Rd South Pittsburg TN 37380...

Отзывы: