8
4.5 SPECIAL MOBILE HOME REQUIREMENTS
WARNING! - Do not install in a sleeping room
CAUTION! - The structural integrity of the mobile home
fl
oor, wall, and ceiling/roof must be maintained
.
In addition to the previously detailed installation requirements, mobile home installations must meet the following requirements:
•
The heater must be permanently attached to the
fl
oor.
1. There are two holes in the pedestal base, use 3/8” bolts through the
fl
oor.
2. To attach the leg model use two 3/8-16 UNC bolts through the
fl
oor.
•
The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire using a serrated or star
washer to penetrate paint or protective coating to ensure grounding.
•
When moving your mobile home, all exterior venting must be removed while the mobile home is being relocated. After relocation,
all venting must be reinstalled and securely fastened.
•
Outside Air is mandatory for mobile home installation. See your dealer for purchasing.
•
Check with your local building of
fi
cials as other codes may apply.
MOBILE HOME ATTACHEMENT