background image

 

5

3.4  INSERT FIREPLACE FACADE ASSEMBLY

Breckwell Room Heaters are available as an insert into existing masonry or factory-built 

fi

 replaces.  

Do not alter the existing 

fi

 replace in any way either by removing bricks or mortar which could weaken the structural integrity 

of the 

fi

 replace. 

1) 

Position stove in 

fi

 replace. Align facade panels with 

fi

 replace and top of stove. The panels should be 

fl

 at against the 

fi

 replace 

and standing vertical. 

Notes: The side facade pieces go behind the top piece. 

 The facade must be installed before unit is set into its 

fi

 nal position.

2) 

Mark the location of the facade panels along the top of the stove with a pencil. The mark will be used to realign the panels later.

3) 

Slide stove out of 

fi

 replace far enough to be able to work behind facade panels.

4) 

Realign the 

fi

 rst side panel with the mark made previously. 

5) 

Using the predrilled holes in the facade panel as a guide; mark and drill holes for the self tapping screws used to mount the 
facade panel. See illustration on right below.  

Note: Align the mounting screws with the center of the predrilled holes to allow for adjustment.

6) 

Repeat steps 4 and 5 for the other side panel.

7) 

Attach side panel trim as shown. See illustration on left below.

8) 

Attach top panel retainer with two self tapping screws.

9) 

Ensure venting is attached properly.

10) 

Align the top panel with the retainer and side panels

11) 

Attach top panel trim. 

Note: Stove and facade panels should realign with 

fi

 replace to allow the panels to be 

fl

 at against 

fi

 replace and standing vertically 

12) 

Attach self adhesive insulation to back of facade and realign stove in 

fi

 replace.

ALIGN MOUNTING 

SCREW WITH 

CENTER OF 

PREDRILLED 

MOUNTING HOLE.

ATTACH 

FACADE TRIM.

Top Panel Retainer

Self-adhesive insulation

Содержание SW180

Страница 1: ...SE INSTRUCTIONS THIS MANUALWILLHELPYOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLEYOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE French version is...

Страница 2: ...Flue Pipe Type Standard Single Wall or Double Wall Black or Blued Steel 2100 F 650 C Minimum Chimney Height 12 3 7m Maximum Log Length 12 304mm Electrical 110 Volt 60 Hz 31 Watt Dimensions Overall wi...

Страница 3: ...e of the three offered kits A Pedestal Kit SA180P B Leg Kit SA180L C Fireplace Insert SA180i Refer to the instructions found inside each kit for proper assembly A 7 16 socket wrench A 5 16 socket Best...

Страница 4: ...that you use cardboard or other means of padding to protect the finish on your new stove 3 2 FREESTANDING LEG ASSEMBLY 1 Unpack the kit and ensure all components are present Qty Description Part 4 Ca...

Страница 5: ...panels 4 Realign the first side panel with the mark made previously 5 Using the predrilled holes in the facade panel as a guide mark and drill holes for the self tapping screws used to mount the faca...

Страница 6: ...Mur Side wall Paroi Lat rale Side wall Paroi Lat rale S de a a o at a e C B A Dimension Inch mm A Backwall to Stove 12 305 B Sidewall to Stove 12 305 C Sidewall to Flue 13 330 D Wall to Stove Angled...

Страница 7: ...ers of listed floor protectors include Imperial Metal Products and Hy C among others To calculate R Values for alternative methods see Alternate Floor Protector Calculation Methods in the back of this...

Страница 8: ...he floor 2 To attach the leg model use two 3 8 16 UNC bolts through the floor The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire using a serrated or...

Страница 9: ...arrier and tight fitting windows and or has any powered devices that exhaust house air 5 There is excessive condensation on windows in the winter 6 A ventilation system is installed in the house If an...

Страница 10: ...ft effect your stove s performance is directly dependent on an adequate draft from your chimney Do not connect this unit to a chimney flue serving another appliance The following recommendations may b...

Страница 11: ...not weaken any structural components of the existing fireplace or chimney nor reduces protection of combustible materials required by national building codes Consult with your local building or fire a...

Страница 12: ...y a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove t...

Страница 13: ...nector and a minimum 24 gauge ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fibergla...

Страница 14: ...d horizontally must slope at least 1 4 inch per foot with the upper end of the section toward the chimney Any installation with a horizontal run of stove pipe must conform to NFPA 211 You may contact...

Страница 15: ...same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance t...

Страница 16: ...lackened windows Incomplete log combustion Smaller pieces of wood will dry faster All logs exceeding 6 in diameter should be split The wood should not be stored directly on the ground Air should circu...

Страница 17: ...d combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for each given situation The wood will burn slowly if the wood stove air...

Страница 18: ...t should be removed to reduce the risk of a chimney fire We strongly recommend that you install a magnetic thermometer on your smoke exhaust pipe approximately 18 above the stove This thermometer will...

Страница 19: ...hed only when cold 7 2 GASKETING It is recommended that you change the door gasket which makes your stove door air tight once a year in order to insure good control over the combustion maximum efficie...

Страница 20: ...Possible Remedies Unplug blower first if equipped Cool exhaust flue gasses Use double or triple wall external chimney Burning unseasoned wet wood Use dry seasoned hardwood Smoke rolls out when feed o...

Страница 21: ...530 FIREBRICK 4 5 x 7 5 x 1 25 2 18 891783 FIREBRICK 3 x 4 1 2 3 19 26706 RIGHT BRICK RETAINER 1 20 26705 LEFT BRICK RETAINER 1 21 69952 HEAT SHIELD 1 22 26703 WINDOW CLAMP 4 23 69953 DOOR ASSEMBLY 1...

Страница 22: ...22 30 28 27 33 32 31 26 25 34 13 29 23 9 22 10 1 14 21 21 11 2 12 8 7 8 4 5 18 3 16 17 19 20 6 15 24 WIRING SCHEMATIC...

Страница 23: ...1 39 26730 BACKING PLATE 1 SA180I Key Part Description Qty 60 26734 Surround Top 1 61 26735 Surround Left 1 62 26736 Surround Right 1 63 26414 Clamp Top Trim 1 64 892340 Trim Kit Sw180 1 65 83386 10...

Страница 24: ...24 NOTES...

Страница 25: ...given with a required thickness T in inches R 1 k x T c C factor is given R 1 C 2 Determine the R value of proposed alternate floor protector a Use formulas in step 1 above to calculate R value of pro...

Страница 26: ...d to the stove When ordering repair parts always give the following information as shown in this list 10 0 HOW TO ORDER REPAIR PARTS 1 The part number SW180 2 The part description ____________________...

Страница 27: ...______ Reason for Purchase Alternative Heat Main Heat Source Decoration Cost Other _________________________ What was the determining factor for purchasing your new appliance _______ I have read the o...

Страница 28: ...28 CUT HERE CUT HERE Fold Here Fold Here Breckwell 227 Industrial Park Road South Pittsburg TN 37380 USA Fold Here PLACE STAMP HERE...

Отзывы: