Your wood stove is a high ef

fi

 ciency stove and therefore requires little maintenance.   It is important to perform a visual inspection 

of the stove every time it is emptied, in order to insure that no parts have been damaged, in which case repairs must be performed 
immediately. Inspect and clean the chimney and connector pipe periodically for creosote buildup or obstructions.

7.1 GLASS

• 

Inspect and clean the glass regularly in order to detect any cracks. If you spot one, turn the stove off immediately. Do not 
abuse the glass door by striking or slamming shut. Do not use the stove if the glass is broken.

• 

If the glass on your stove breaks, replace only with the glass supplied from your heater dealer. Never substitute other materials 
for the glass.

• 

To replace the glass, remove the screws retaining the glass mouldings inside the door.  Remove the mouldings and replace 
the damaged piece with a new one. Perform the procedure backwards after replacing. When replacing the glass, you should 
change the glass gasket to make sure you keep it sealed.

• 

Never wash the glass with a product that may scratch. Use a specialized product, available in the stores where wood stoves 
are sold. The glass should be washed only when cold.

7.2 GASKETING

It is recommended that you change the door gasket (which makes your stove door air tight) once a year, in order to insure good 

control over the combustion, maximum ef

fi

 ciency and security. To change the door gasket, simply remove the damaged one.  Carefully 

clean the available gasket groove, apply a high temperature silicone sold for this purpose and install the new gasket. You may light 
up your stove again approximately 24 hours after having completed this operation.

WARNING:

NEVER OPERATE THE STOVE WITHOUT A GASKET OR WITH A BROKEN ONE. DAMAGE TO THE STOVE OR 

EVEN HOUSE FIRE MAY RESULT.

7.3 PAINT

Only clean your stove with a dry soft cloth that will not harm the paint 

fi

 nish.  If the paint becomes scratched or damaged, it is 

possible to give your wood stove a brand new look by repainting it with a 1200° F heat resistant paint. For this purpose, simply scrub 
the surface to be repainted with 

fi

 ne sand paper, clean it properly, and apply thin coats (2) of paint successively.

7.4 BLOWER (IF EQUIPPED)

The blower needs to be removed and air blown clean. Make sure the blades do not have build up.

7.5 SECONDARY AIR TUBES

The secondary air tubes must be cleaned with a wire brush. If debris remains in holes lightly tap with a wooden stick to remove.

7.6 FIREBRICK

The 

fi

 rebrick should be cleaned and inspected as necessary. Replace any damaged or broken brick.

7.0 

 

     MAINTENANCE

Содержание SW180

Страница 1: ...SE INSTRUCTIONS THIS MANUALWILLHELPYOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLEYOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE French version is...

Страница 2: ...Flue Pipe Type Standard Single Wall or Double Wall Black or Blued Steel 2100 F 650 C Minimum Chimney Height 12 3 7m Maximum Log Length 12 304mm Electrical 110 Volt 60 Hz 31 Watt Dimensions Overall wi...

Страница 3: ...e of the three offered kits A Pedestal Kit SA180P B Leg Kit SA180L C Fireplace Insert SA180i Refer to the instructions found inside each kit for proper assembly A 7 16 socket wrench A 5 16 socket Best...

Страница 4: ...that you use cardboard or other means of padding to protect the finish on your new stove 3 2 FREESTANDING LEG ASSEMBLY 1 Unpack the kit and ensure all components are present Qty Description Part 4 Ca...

Страница 5: ...panels 4 Realign the first side panel with the mark made previously 5 Using the predrilled holes in the facade panel as a guide mark and drill holes for the self tapping screws used to mount the faca...

Страница 6: ...Mur Side wall Paroi Lat rale Side wall Paroi Lat rale S de a a o at a e C B A Dimension Inch mm A Backwall to Stove 12 305 B Sidewall to Stove 12 305 C Sidewall to Flue 13 330 D Wall to Stove Angled...

Страница 7: ...ers of listed floor protectors include Imperial Metal Products and Hy C among others To calculate R Values for alternative methods see Alternate Floor Protector Calculation Methods in the back of this...

Страница 8: ...he floor 2 To attach the leg model use two 3 8 16 UNC bolts through the floor The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire using a serrated or...

Страница 9: ...arrier and tight fitting windows and or has any powered devices that exhaust house air 5 There is excessive condensation on windows in the winter 6 A ventilation system is installed in the house If an...

Страница 10: ...ft effect your stove s performance is directly dependent on an adequate draft from your chimney Do not connect this unit to a chimney flue serving another appliance The following recommendations may b...

Страница 11: ...not weaken any structural components of the existing fireplace or chimney nor reduces protection of combustible materials required by national building codes Consult with your local building or fire a...

Страница 12: ...y a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove t...

Страница 13: ...nector and a minimum 24 gauge ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fibergla...

Страница 14: ...d horizontally must slope at least 1 4 inch per foot with the upper end of the section toward the chimney Any installation with a horizontal run of stove pipe must conform to NFPA 211 You may contact...

Страница 15: ...same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance t...

Страница 16: ...lackened windows Incomplete log combustion Smaller pieces of wood will dry faster All logs exceeding 6 in diameter should be split The wood should not be stored directly on the ground Air should circu...

Страница 17: ...d combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for each given situation The wood will burn slowly if the wood stove air...

Страница 18: ...t should be removed to reduce the risk of a chimney fire We strongly recommend that you install a magnetic thermometer on your smoke exhaust pipe approximately 18 above the stove This thermometer will...

Страница 19: ...hed only when cold 7 2 GASKETING It is recommended that you change the door gasket which makes your stove door air tight once a year in order to insure good control over the combustion maximum efficie...

Страница 20: ...Possible Remedies Unplug blower first if equipped Cool exhaust flue gasses Use double or triple wall external chimney Burning unseasoned wet wood Use dry seasoned hardwood Smoke rolls out when feed o...

Страница 21: ...530 FIREBRICK 4 5 x 7 5 x 1 25 2 18 891783 FIREBRICK 3 x 4 1 2 3 19 26706 RIGHT BRICK RETAINER 1 20 26705 LEFT BRICK RETAINER 1 21 69952 HEAT SHIELD 1 22 26703 WINDOW CLAMP 4 23 69953 DOOR ASSEMBLY 1...

Страница 22: ...22 30 28 27 33 32 31 26 25 34 13 29 23 9 22 10 1 14 21 21 11 2 12 8 7 8 4 5 18 3 16 17 19 20 6 15 24 WIRING SCHEMATIC...

Страница 23: ...1 39 26730 BACKING PLATE 1 SA180I Key Part Description Qty 60 26734 Surround Top 1 61 26735 Surround Left 1 62 26736 Surround Right 1 63 26414 Clamp Top Trim 1 64 892340 Trim Kit Sw180 1 65 83386 10...

Страница 24: ...24 NOTES...

Страница 25: ...given with a required thickness T in inches R 1 k x T c C factor is given R 1 C 2 Determine the R value of proposed alternate floor protector a Use formulas in step 1 above to calculate R value of pro...

Страница 26: ...d to the stove When ordering repair parts always give the following information as shown in this list 10 0 HOW TO ORDER REPAIR PARTS 1 The part number SW180 2 The part description ____________________...

Страница 27: ...______ Reason for Purchase Alternative Heat Main Heat Source Decoration Cost Other _________________________ What was the determining factor for purchasing your new appliance _______ I have read the o...

Страница 28: ...28 CUT HERE CUT HERE Fold Here Fold Here Breckwell 227 Industrial Park Road South Pittsburg TN 37380 USA Fold Here PLACE STAMP HERE...

Отзывы: