AWT35-100089 Rev AA
20/25
CONFIG
SubMenu1 SubMenu2 Option
Default
Description
RESET
YES /
NO
NO
Resets the configuration to factory setting.
REGULA
NONE
NONE
Do not use.
See SBI 210-LCD Operation Manual.
USA
CANADA
EUROPE
PRIM.N
2000
Sets the number of divisions (div) of the
primary unit of measure (lb).
PRIM.D
100
~
100000
0.5
Sets the weight division (1 div = 0.5 lb) value
of the first unit of measure.
The division value of the secondary unit of
measure (1 div = 0.2 kg) is automatically
determined by the indicator according to the
first unit.
PRIM.Ut
kg /
lb
lb
Selects the primary unit of measure: kg or lb.
The default calibration unit is the primary unit.
SECND.N
100
~
125000
2500
Sets the number of divisions (div) of the
secondary unit of measure (kg).
Max 1.25*(PRIM.N)
MOTION
1
~
255
4
Sets the in-motion weight divisions range:
1
~
255
= ±0.25div * (1~255)
OVER.LD
0
~
100
0
Sets the overload weight limit:
0
= FS + 9 div
1~100 = 101%FS ~ 200%FS
UNITS
kg
YES
/
NO
YES
Sets the active unit of measure:
Yes
= enable the unit;
No
= the unit is not active.
lb
YES
/
NO
YES
oz
YES /
NO
NO
lb oz
YES /
NO
NO