background image

AWT35-100089 Rev AA 

 

5/25 

 

1  Warnings 

 

United States 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 

Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 

interference when the equipment is operated in a commercial environment. This equipment generates, uses, 

and can radiate radio frequency energy and, if not installed and used in accordance with the instruction 

manual, may cause harmful interference to radio communications. Operation of this equipment in a 

residential area is likely to cause harmful interference in which case the user will be required to correct the 

interference at his own expense. 

 

Canada 

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus 

set out in the Radio Interference Regulations of the Canadian Department of Communications. 

 

Le présent appareil numérique n’ émet pas de bruits radioélectriques dépassant les limites applicables aux 

appareils numériques de la Classe A prescrites dans le Règlement sur le brouillage radioélectrique edicté 

par le ministère des Communications du Canada 

 

1.1 Safe installation 

 

 

 

THE EQUIPMENT CONTAINS NO USER SERVICEABLE COMPONENTS. 

Installation and maintenance of the equipment must only be carried out by trained and 

authorized personnel. 

 

 

 

 

Electrical installation 

The mains lead must be connected to a supply outlet with a protective earth contact. The 

electrical supply  at the socket outlet must provide over current protection of an appropriate 

rating. 

For your protection all mains (110V or 230V) equipment used out of doors or in wet or damp 

conditions  should be supplied from a correctly fused source and protected by an approved 

ground fault protection device (RCD, GFCI etc.) 

IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN. 

 

 

 

Routine maintenance 

To avoid the possibility of electric shock or damage to the machine, always switch off the 

machine and isolate from the power supply before carrying out any routine maintenance. 

To avoid the risk of the machine falling, where applicable, ensure that it is placed securely on a 

flat and level surface. 

 

 

1.2 Safe use 

 

Caution – Cleaning the indicator/weigh head 

Harsh abrasives, solvents, scouring cleaners and alkaline cleaning solutions, such as washing soda, 

should not be used especially on the display windows. Under no circumstances should you attempt to 

wipe the inside of the machine. 

The outside of standard products may be wiped down with a clean cloth, moistened with water containing 

a small amount of washing up liquid. 

 

Training 

Do not attempt to carry out any procedure on a machine unless you have received the appropriate 

training or read the Instruction Manual. 

 

EMC compliance 

The following may be applicable to your machine. 

 

WARNING: This is a class A product. In a domestic environment this product may cause radio interference 

in which case the user may be required to take adequate measures. 

 

 

 

Содержание 810036380263

Страница 1: ...Model MS 1000 LCD Operator Manual AWT35 100089 Rev AA...

Страница 2: ...roduct names used within this document are trademarks or registered trademarks of their respective holders Groupe de soci t s Avery Weigh Tronix 2021 Tous droits r serv s Aucune partie de cette public...

Страница 3: ...mple Weighing 9 3 2 Tare Weighing 9 3 3 Changing Units 9 3 4 BMI Function 10 3 5 Print Function Com Ports 10 3 6 Hold Function 10 3 6 1 Automatic Hold Mode Default 11 3 6 2 Average Hold Mode 11 3 6 3...

Страница 4: ...AWT35 100089 Rev AA 4 25 Manual revision history Current Issue Date Created Details of Changes AWT35 100089 Rev AA Sep 2021 New...

Страница 5: ...he mains lead must be connected to a supply outlet with a protective earth contact The electrical supply at the socket outlet must provide over current protection of an appropriate rating For your pro...

Страница 6: ...place the MS1000 platform in a location that will not degrade its accuracy Try to avoid placing the scale in direct sunlight or near air vents Place the scale on a level flat surface It is not advise...

Страница 7: ...of measure Battery status or AC DC operated 2 5 2 Operation Keys The key functions are listed below In menu mode the keys have secondary functions Enters exits the HOLD mode In Menu mode go to previou...

Страница 8: ...AWT35 100089 Rev AA 8 25 Zeroes the scale turns the scale on off In Menu mode cancel an operation and exit from the current working mode...

Страница 9: ...wer up the scale and zero the display if necessary by pressing the ZERO ON OFF key Be sure the scale is displaying weight in your preferred unit of measure Press the UNIT key if necessary 2 Place the...

Страница 10: ...full duplex RS 232 serial port and USB port designed for connection to either a PC or a serial printer The Print function sends the data out to the RS232 USB ports Use the correspondent adapter to con...

Страница 11: ...weighments 5 Press the HOLD key to exit the current mode If the weight oscillations exceed the HLD RNG division range value 5 div within the STB TIM time value 15 sec the indicator will display STB ER...

Страница 12: ...LD key to enable this function The Hold annunciator flashes 3 Step on the scale If the weight sensed is stable for STB TIM 15 s and above the NLD RNG zero range 10 div 5 lb 2 kg the indicator displays...

Страница 13: ...TARE key to confirm or the ZERO ON OFF key to cancel the operation exit the menu 4 1 1 User Options USER SubMenu1 SubMenu2 Option Default Description RESET NO NO NO Returns the USER parameter to the f...

Страница 14: ...GLE EH SCP SCP 12 Eh sp2 Lfuulf Lfuu Lf lf Lf uulf uu lf USB Port com2 BAUD RT 600 9600 Sets the baud rate of com2 1200 2400 4800 9600 19200 BYT FMT 8N1 8N1 Sets the bits format of com2 7O1 7E1 7O2 7E...

Страница 15: ...OMPAR mode NONE NONE COMPARE function modes NONE disabled See SBI 210 LCD Operation Manual and Config Compar L LOW IN LMT O HIGH OUT LMT HOLD Function HLD MOD NONE AUTO Enables the HOLD function mode...

Страница 16: ...div range can be averaged NLD RNG No Load Detected Range 1 255 10 Sets the weight range that the indicator considers as the Zero range for the relevant function e g Auto Hold Mode 1 255 the range of...

Страница 17: ...cator displays 2 TD 55 and the serial port continuously transmits 0x55 Use the and keys to change the character USB RD USB receive data testing same as RS232 receiving data testing USB TD USB send dat...

Страница 18: ...the TARE key to confirm or the ZERO ON OFF key to cancel the operation exit the menu CAL SubMenu1 SubMenu2 Option Description ZERO Adjusts the CAL P0 point only LINE CAL P0 Stores the Zero calibration...

Страница 19: ...platform 9 Press the TARE key to store the CAL P1 Point 10 Press the TARE key to save the calibration points and exit the Calibration mode or press the PRINT key to add CAL P2 3 points On calibration...

Страница 20: ...dary unit of measure 1 div 0 2 kg is automatically determined by the indicator according to the first unit PRIM Ut kg lb lb Selects the primary unit of measure kg or lb The default calibration unit is...

Страница 21: ...ght is outside the IZSM range DSP OVR if the initial zero is over range display the 0 error WEIGHT current weight CAL ZRO calibration zero LAST Z T last zero tare value WEIGHT CAL ZRO LAST Z T SAZSM 0...

Страница 22: ...25 COMPAR YES NO NO No disabled See SBI 210 LCD Operation Manual ACCUMU NO MANUAL AUTO NO No disabled See SBI 210 LCD Operation Manual GEO CAL YES YES Yes enables the Geographical Adjustment Factor i...

Страница 23: ...9V 600MA adaptor body with USA plugs included and 6xAA batteries not included Operating temperature range 32 104 F 0 40 C max relative humidity 80 at 86 F 30 C Communication interface RS 232 USB Port...

Страница 24: ...r 1 initial zero error 1 low battery 4 always 1 always 1 always 1 always 1 5 always 1 always 1 always 1 always 1 6 always 0 always 1 always 1 always 0 7 parity Parity parity Parity Command Response AS...

Страница 25: ...weighing range 1 Over capacity 2 0 Within weighing range 1 Under zero 3 0 Within range 1 Outside zero capture range 4 0 Not at center of zero 1 Center of zero 5 always 1 6 always 1 7 parity Command Re...

Страница 26: ...ty 1 Not at zero 0 Not over capacity 2 0 RAM error 1 ROM error 1 RAM okay 0 ROM okay 3 0 EEPROM error 1 Faulty calibration 1 EEPROM okay 0 Calibration okay 4 Always 1 Always 1 5 always 1 always 1 6 al...

Страница 27: ...D Simulate ZERO key no response from scale others Un known commands LF CR EH SP2 MM Status Byte gg Scale in motion GG Stable weight data Command Response ASCII HEX CR 0d Read scale weight P W1W2W3 dp...

Страница 28: ...ll free 800 637 0529 Tel 507 238 8702 Fax 507 238 8271 Email sales brecknellscales com http brecknellscales com Brecknell UK Foundry lane Smethwick West Midlands England B66 2LP Tel 44 0 8452 466717 F...

Отзывы: