background image

©  BREATHESAFE  2021   

 

PAGE  4        

 

www.breathe-safe.com.au 

                          Delivering  Innovative  Climate  Solutions  Worldwide

Controlled document:

Issue Date: 

C o n t e n t s

1 USER GUIDE

1 Key Features

2 WARNING

3 CONTROLLER APPEARANCE

4 FUNCTIONS

5 OPERATING INSTRUCTIONS

5 Enter Setup Mode
6 Change Date and Time
6 Change Pressure Setpoint
6 Change ALarm Setpoint
7 Enable / Disable Buzzer
7 Change Alarm DELAY Settings
7 Change Service Reminders
8 Calibrate Zero Sensor
8 Reset Data Log
8 Test Inputs Option

9 TECHNICAL DETAILS

9 Map of Functions
11 General Arrangement
12 Connector Pinout Details
14 Installation
15 Fan Speed Control Output 
15 Mounting
15 Supply Power 
15 Calibration 
15 Control Override
16 Data Logging Information

20 BREATHESAFE WARRANTY

21 CONTACT US

I N P R E S S   T S

Controlled document:

 M-0002B

Revision: 

B

Issue Date: 

30 August 2021

FUNCTIONS

AUTOMATIC CABIN PRESSURE

The INPRESS TS is an intelligent pressuriser controller that monitors 

the pressure difference from inside to outside of the cabin. It controls 

the speed of the motor to maintain a set pressure difference. 

LOW PRESSURE ALARM

If the cabin pressure falls below the alarm setpoint, INPRESS TS will 

wait the designated delay time before alarming user. 
The alarm will sound, and LOW-PRESSURE WARNING will flash on 

screen in red lettering. Press the ALARM button to mute the alarm.  

At the same time as this alert is sounding, the fan power will increase 

to maximum to keep operator as safe as possible.

ALARM DELAY

There is a designated delay time between the TS measuring low 

pressure and sounding the delay. This gives allowances in time for 

small changes like opening window briefly. The amount of delay can 

be changed in settings.

SERVICE REMINDERS

The INPRESS TS has automatic reminders for servicing of filter system. 

The default is 500 runtime hours, but can be altered in settings.

DATA LOGGING

By default, the BreatheSafe INPRESS TS  unit starts data logging as 

soon as power is applied. This feature cannot be stopped or disabled.  
Data logging records time, date, pressure reading, and any alarms  

activated during operation.

LIGHT SENSOR

The light sensor automatically adjusts screen brightness for operator 

safety and minimised distraction

GRAPHIC DISPLAY OF PRESSURE CHANGE

A graphic display is available for a visual representation of the 

pressure inside cabin over time since turned on.

Graph Screen

Содержание INPRESS TS

Страница 1: ...ly designed to monitor record and intelligently control the cabin pressure inside a vehicles cabin or electrical enclosure Efficient cabin air filtration and pressure management ensure harmful dust an...

Страница 2: ...ata Logging Information 20 BREATHESAFE WARRANTY 21 CONTACT US I N P R E S S T S Controlled document M 0002B Revision B Issue Date 30 August 2021 WARNING THE PRESSURISATION SYSTEM DESCRIBED IN THIS MAN...

Страница 3: ...Reminders 8 Calibrate Zero Sensor 8 Reset Data Log 8 Test Inputs Option 9 TECHNICAL DETAILS 9 Map of Functions 11 General Arrangement 12 Connector Pinout Details 14 Installation 15 Fan Speed Control O...

Страница 4: ...E ALARM If the cabin pressure falls below the alarm setpoint INPRESS TS will wait the designated delay time before alarming user The alarm will sound and LOW PRESSURE WARNING will flash on screen in r...

Страница 5: ...21 CONTACT US I N P R E S S T S Controlled document M 0002B Revision B Issue Date 30 August 2021 OPERATING INSTRUCTIONS ENTER SETUP MODE Start Up Screen Main Screen Settings Button Settings Screen Sit...

Страница 6: ...sure that sets the alarm off Low pressure can allow hazardous particals into the cab and can occur when doors or windows are left open or if there is an issue with the sealing Enter Setup mode and sel...

Страница 7: ...ccess Button Adjust Setpoint Enter Setup mode and select ADJUST SETPOINT button To disable buzzer toggle through ENABLED and DIABLED button When set correctly press the SAVE button CHANGE ALARM DELAY...

Страница 8: ...untime the INPRESS TS may need to be recalibrated This screen allows the sensor to be recalibrated if more than 5Pa out To recalibrate open windows and doors turn off air conditioning and any other de...

Страница 9: ...isable Buzzer 7 Change Alarm DELAY Settings 7 Change Service Reminders 8 Calibrate Zero Sensor 8 Reset Data Log 8 Test Inputs Option 9 TECHNICAL DETAILS 9 Map of Functions 11 General Arrangement 12 Co...

Страница 10: ...etpoint 7 Enable Disable Buzzer 7 Change Alarm DELAY Settings 7 Change Service Reminders 8 Calibrate Zero Sensor 8 Reset Data Log 8 Test Inputs Option 9 TECHNICAL DETAILS 9 Map of Functions 11 General...

Страница 11: ...rm Setpoint 7 Enable Disable Buzzer 7 Change Alarm DELAY Settings 7 Change Service Reminders 8 Calibrate Zero Sensor 8 Reset Data Log 8 Test Inputs Option 9 TECHNICAL DETAILS 9 Map of Functions 11 Gen...

Страница 12: ...Map of Functions 11 General Arrangement 12 Connector Pinout Details 14 Installation 15 Fan Speed Control Output 15 Mounting 15 Supply Power 15 Calibration 15 Control Override 16 Data Logging Informati...

Страница 13: ...D OUT CHASSIS COM PORT CONNECTION Warning Lamp If higher current output is required an external relay must be fitted 0V GND 1 6 2 7 3 8 4 9 5 DB9 CONNECTION FOR DATA RETRIEVAL PORT SETTINGS Baud Rate...

Страница 14: ...SAFE WORK PROCEDURES AND ELECTRICAL SAFETY MEASURES BEING TAKEN AND ALL RELEVANT CIRCUIT BREAKERS OPENED TO ISOLATE THE CIRCUIT THE AIR FILTRATION SYSTEM MAY HAVE SEVERAL TYPES OF HIGHSPEED ROTATING...

Страница 15: ...roprietary housing to secure the unit Mounting can be in any orientation preferably internally and positioned such that the operator can monitor the cabin pressure ensuring their working environment i...

Страница 16: ...will return to the Factory Settings Screen on completion GET REAL TIME LOG Pressing this button begins the output of the log data to the terminal software installed on your computer The logging interv...

Страница 17: ...l Output 15 Mounting 15 Supply Power 15 Calibration 15 Control Override 16 Data Logging Information 20 BREATHESAFE WARRANTY 21 CONTACT US I N P R E S S T S Controlled document M 0002B Revision B Issue...

Страница 18: ...angement 12 Connector Pinout Details 14 Installation 15 Fan Speed Control Output 15 Mounting 15 Supply Power 15 Calibration 15 Control Override 16 Data Logging Information 20 BREATHESAFE WARRANTY 21 C...

Страница 19: ...ct all Select Copy table Open blank excel document and click on the page Right click to paste the copied table Fields are date time motor volts output cabin pressure Pa cabin pressure preset Pa cabin...

Страница 20: ...21 CONTACT US I N P R E S S T S Controlled document M 0002B Revision B Issue Date 30 August 2021 BREATHESAFE WARRANTY We warrant all goods to be of good material and workmanship and will replace at ou...

Страница 21: ...ECHNICAL DETAILS 9 Map of Functions 11 General Arrangement 12 Connector Pinout Details 14 Installation 15 Fan Speed Control Output 15 Mounting 15 Supply Power 15 Calibration 15 Control Override 16 Dat...

Отзывы: