6.2
Protection function
6.2.1
Compressor protection
When the required temperature is reached or the power supply is cut off, the compressor will stop
working for 3 minutes.
6.2.2
Water source low pressure protection
When the water source pressure is lower than 100 kPa or the water source switch is shut off, the water
inlet valve and pump power will be cut off to have them protected in order to avoid long
−
time running.
6.2.3
Power failure memory function
The setting parameter will not change after a power
−
cut. The machine can go on running as before.
6.2.4
”E1” protection function
When something is wrong with the temperature sensor or a connection loose, the digital display will
show ”E1”. The device will stop working by control system unless the fault I has been solved.