EN
E
Copyright Bravilor Bonamat B.V.
7
5.3.1.2
Chiller (Type II)
1. Close the water tap.
2. Use button 3 to draw off the CO
2
reservoir until only CO
2
gas escapes (
±
84.54 fl oz water).
3. Fill the cleaning cartridge with the two bottles of detergent.
4. Connect the cleaning cartridge to the Chiller.
5. Turn the water tap open.
6. Use button 2 to draw off approximately 8.45 fl oz of water.
7. Wait for about 30 minutes, the Chiller will now fill with the cleaning agent.
8. Remove the cleaning cartridge and empty the water present.
9. Use the spray bottle to clean the outlet, during the filling process.
10. Close the water tap.
11. Use button 3 to draw off the CO
2
reservoir until only CO
2
gas escapes (
±
84.54 fl oz water).
12. Turn the water tap open.
13. Use button 2 to draw off approximately 33.8 fl oz of water.
14. The Chiller fills up again and after approx. 20 minutes ready for use.
15. Use button 3 to draw off the CO
2
reservoir until only CO
2
gas escapes (
±
84.54 fl oz water).
16. If a water filter is connected it should also be replaced now (see § 3.2.3).
17. Reset the timer for cleaning (see § 6.1.2).
The device is ready for use.
TIP
−
Ensure that there is always at least one spare water filter in stock.
−
Clean the ventilator and the outside of the condenser every year (if necessary with a vacuum
cleaner).
CAUTION!
−
The remaining maintenance activities are strictly reserved for specially trained service engineers for
cold
−
water systems.