Brander TR6026 NG Скачать руководство пользователя страница 10

1.

Ensure control knob on heater is in the

 

OFF position.

2.

Open valve for fuel supply.

3.

Turn control knob to  position.

 

Press  igniter button multiple times to light burner. When

burner is lit, continue to press and

 

hold down control knob for 30 seconds.  This engages the

thermocouple.

 

If burner does not light, release control knob and turn it clockwise to the OFF

position. Wait 5

 

minutes. Repeat steps 2 to 3.

4.

If igniter does not work properly, you may light heater manually by inserting a match through

the opening at base of burner (6), as shown in figure 1.

5.

Turn control knob counter clockwise to adjust flame to desired temperature for comfort

Operating The Heater

To Turn Off

1.

Turn control knob fully clockwise.

2.

Tu

rn off gas supply at source.

3.

If heater is not used for long periods, remove from gas

 

source.

Preventative Care and Maintenance

To ensure long-lasting enjoyment of your Patio Heater, the burner should be inspected 
regularly for debris such as insects and spider webs.  

Have 

Heater Inspected If

-Y

ou smell gas combined with yellow flame tips on burne

r

-H

eater does not provide expected heat capacity

-A

bnormal sounds occur during operation

Also...

 

-Periodically check for leaks in the system or immediately when you smell gas.
-In case a leak is detected, extinguish all open flames in the area.
-Never leak test while smoking or with an open flame.
-If you cannot repair a leak, ensure gas supply is turned OFF 

a

nd

 

contact the retailer 

where

you 

purchased the heater, a qualified technician, or your gas supplier.

-Do not modify this heater in any way.
-Replacement parts must only be with original parts.
-The installation of this appliance should be performed by a certified gas technician in
conformity

 

with all building and municipal codes.

10

Содержание TR6026 NG

Страница 1: ...equirements 5 Assembly instructions 6 7 Leak testing the connections 8 Choosing a location for the heater 9 Operating the heater 10 Storage and maintenance 10 CAREFULLY READTHIS GUIDE AND ALL SAFETY I...

Страница 2: ...fety 1 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance 2 LP cylinders not connected for use shall not be stored in the vicinity of thi...

Страница 3: ...flame c Proceed to a leak test see bottom of page 4 d If you still smell gas shut off heater completely and gas valve at cylinder Call the retailer where you purchased the heater or contact a gas appl...

Страница 4: ...ntenance and repair of this heater should always be performed by a qualified gas technician Leak Testing The Connections When the heater is partially assembled step F perform a leak test on all connec...

Страница 5: ...heels see page 9 TOOLS AND EQUIPMENT REQUIRED 10 and 13 mm keys Adjustable wrench Philips screwdriver medium blade Leak test solution mix 50 50 water and soap 6 x Bolts M6 X 55 4 x Bolts M8 X 55 4 x B...

Страница 6: ...e base Once the pole is attached to the base with the three nuts and bolts provided the bottom of the base should look like photo iii Ensure the bolts are not over tightened to the plate Once all seve...

Страница 7: ...ole B Place the post on the top of the weighted box with black plate attached on bottom Then connect them with 6pcs M6x55 bolts and 6pcs M6 bolts Figure 3 C Attach the base over the post to the weight...

Страница 8: ...o test gas system as indicated on page 4 Make sure to test hose and all connections for leaks Lift burner head and test hose connection to burner head G Place burner head so control button is vertical...

Страница 9: ...ge This heater is certified for outdoor use only J CLEARANCES FROM COMBUSTIBLES Respect clearances as shown Sides of reflector 24 inches 61CM Above reflector 18 inches 46 CM Figure 10 Provide fresh ai...

Страница 10: ...r long periods remove from gas source Preventative Care and Maintenance To ensure long lasting enjoyment of your Patio Heater the burner should be inspected regularly for debris such as insects and sp...

Страница 11: ...essure is low Check connection to gas supply Blockage in orifice Clear blockage Flame won t light Control knob is not in ON position Turn control knob to ON Supply hose is bent or kinked Straighten ho...