2.3 Scenarios

SCENARIOS   03

*

 

 

▼ ▲ 

CHANGE SCENAR. 01

GOING OUT

 

▲ 

AREA ACTIONS   01

EXACT ON+OFF

Actions on areas:

 (Default: 

EXACT ON+OFF

)                                                     

 

S

 

A

Associated areas:

                                                             

F

 

S

 

A

The parameter defines the action that the scenario is to carry out in the areas specified 

in 

AREAS ASSOCC.

.

DISABLED

 

 

The scenario does not alter the switched on status of the areas.

 

Example:

 scenario that is disabled or managed only for the associated 

output defined in 

OUTPUT ASSOC

 .

EXACT ON+OFF

 

The selected areas will switch on and those

 

deselected will 

switch off in forced manner in the exact defined configuration.

 

Example:

 it is the one most commonly used and allows the User to set the 

switch-on status of the areas by selecting a scenario independent from 
the previous configuration.

 

LEAVING HOME 

###

; day, night, perimetral areas are on;

 

GOING TO BED

 

#-#

; only day and perimetral are on and night is off;

 

STAYING INDOORS 

--#

; only perimetral is on.

ON SEL.AREAS

 

Only the selected areas switch on, nothing changes about the 

status

 

of the non selected areas.

 

Example: 

used when the user wishes to turn on some areas in a specific mode; 

for example, a scenario that enables only perimetral (PERIMETER ON 

--#

).

OFF SEL.AREAS

 

Only the selected areas switch off, nothing changes about the 

status

 

of the non selected areas.

 

Example:

 used when the user wants to switch off  some areas in a 

specific way; for example, a scenario that switches off only perimeter 
(PERIMETER OFF 

--#

).

SWITCH SEL. AREAS

 

The selected areas change status: if on they switch off and if 

off they switch on.

 

Example: used to group into a single scenario  switch on and off actions 
of several areas. For example a scenario that switches on/off only the 
perimeter area (SWITCH PERIMETER 

--#

).

 

▼ 

*

 

 

▼ ▲ 

 

▼ ▲ 

AREAS ASSOCC.  01

###

OUTPUT ACTION 01

DISABLED

Output action and output association: 

(Default:

 

DISABLED

)

                

S

 

A

If activated, it lets command an output from a scenario. Select the output to command 
in the

 

OUTPUT ASSOC

    

 .

DISABLED

 

The scenario does not command any output.

 

scenario disabled or scenario to manage areas only.

 

The scenario activates the selected output.

 

scenario that opens a lock controlled by  a timed exit. Or a scenario that 
switches on a light commanded by a stable-type output.

 

The scenario deactivates the selected output.

 

scenario that allows to switch-off a light controlled by a stable-type 
output.

 

The scenario exchanges the status of the selected output (if on 

it becomes off, if off it becomes on).

 

scenario that groups on and off for a light controlled by a stable-type 
output.

OUTPUT ASSOC. 01

NO

 

+ - 

 

+ - 

 

+ - 

Scenario description:                                                                                                

 

F

 

S

 

A

For editing the scenario description.

DESCRIPTION  01

GOING OUT

*

 

Содержание Proxinet 8

Страница 1: ...PROGRAMMING MANUAL SECURITY ALARM CONTROL UNIT English EN English EN...

Страница 2: ...m INDEX 1 SYMBOLS AND GLOSSARY PAGE 2 2 TECHNICAL MENU PAGE 3 ACCESSING THE TECHNICAL MENU 3 2 1 PROGRAMMING MODE 3 MENU ITEMS BELONGING TO OTHER MODES 3 EASY MODE 4 STANDARD MODE 4 ADVANCED MODE 4 2...

Страница 3: ...andard system parameters are available ADVANCED all configurable parameters are available Passing from Advanced to Easy means automatic reconfiguring of the parameters which will be hidden Following a...

Страница 4: ...ed to the NIGHT TIME area From a positive with NIGHT area switched off U3 Fault yields a negative if faults are detected U2 System status yields a negative if at least one area is switched on U4 Techn...

Страница 5: ...e set 0 4 KEYPADS Keypads Default F S A Use the keys to enable the keypads used Example if you want to use 4 keypads on the system set 0 4 INSERTERS MITHO TOUCH YES Inserters Default F S A Use the key...

Страница 6: ...s INPUT TEST LAUNCH TEST AREAS TO TEST CRT U TAMP TEST LAUNCH TEST Control unit battery test F S A For promptly checking control unit battery status CRT U BATT TEST LAUNCH TEST SIRENS TEST LAUNCH TEST...

Страница 7: ...IPADDR MODIF 255 255 255 000 NETMASK MODIF 192 168 001 001 GATEWAY MODIF IP COMPUTER PORT 36821 MODIF Network board automatic addressing A Enables disables auto addressing DHCP Keypad emulation PXWEB...

Страница 8: ...ple a scenario that enables only perimetral PERIMETER ON OFF SEL AREAS Only the selected areas switch off nothing changes about the status of the non selected areas Example used when the user wants to...

Страница 9: ...In this case the triggering of the alarm will inevitably warn that the system has been left with open inputs DEPENDENCY 01 Dependence Default A An area s dependence ties its switched on state to that...

Страница 10: ...ted areas Cod 2 Employee associated areas SCENARIOS 01 CHANGE LIST Scenarios Default A sc 1 B sc 2 C sc 3 4 sc 4 S A Associates the scenarios to the keys on the keypad Use the arrow keys to select the...

Страница 11: ...ING TO BED Scenarios Default L1 sc 1 L2 sc 2 L3 sc 3 S A Associate the scenarios to the three inserter LEDs Use keys to edit the scenario associated to the inserter led Example a home with three area...

Страница 12: ...en FAULT It remains enabled with control unit engaged and disengaged The Fault Led light up for any malfunctions and breakdown output is enabled The system displays the ANOMALY message followed by the...

Страница 13: ...s switch off Impulsive switching on off When input is unbalanced the associated areas exchange status when off they switch on and when on they switch off Stable switching on off When input is unbalanc...

Страница 14: ...the associated areas are switched on and is delayed if partialised at least one area switched off and one switched on Example this parameter is set when it is necessary for the door to be delayed type...

Страница 15: ...you can set this input Example two sensors point to the same room and the user wants an alarm to be issued when both sensors go into alarm mode INPUT 1 Type INSTANTANEOUS And input INPUT 2 INPUT 2 Ty...

Страница 16: ...tput is commanded by the input s status More precisely the output is activated if the input is unbalanced and restored if the input is balanced ON ACTION 001 PULSE ON OFF Parameter viewable only if th...

Страница 17: ...tion Default 000 S A Duration time of the impulsive output activation Example opening a door lock via code An impulsive output is associated to a code with a 3 second activation time IMPULSE TIME 001...

Страница 18: ...t as a function of another output Example we want two outputs on the general alarm bus Output 10 type STABLE Output 21 type STABLE follows output OUTPUT 10 In the outputs Association menu assign gener...

Страница 19: ...e Default 090 F S A Alarm time associated to technical type inputs BURGL ALARM 0 255 SEC 000 Burglary alarm time Default 000 F S A Alarm time associated to burglary type inputs BUZZER OUTPUT 01 0 255...

Страница 20: ...gle areas A Telephone notifications associated to both activation and restoration of the single area s sabotage alarm the alarm is given by the inputs associated to the areas Use to select the areas U...

Страница 21: ...AT FAILURE PHONE NOT MENU 05 TRN ON TRN OFF TOTAL SYSTEM ON Total switching on switching off and partialisation of the system F S A Telephone notifications associated to complete switching on complete...

Страница 22: ...inserters Use to select the keys Use the keys to set the phone numbers ACT INP ALRM 001 Activating and restoring generic alarm of single inputs A Telephone notifications associated to both activation...

Страница 23: ...ault NO S A For selecting the output to associate to the single area s ready status an area is deemed ready when none of its associated inputs is open AREA ON 01 NO Generic alarm area switched on Defa...

Страница 24: ...om a PC is only allowed when the control unit is completely switched off i e no areas are switched on and the User code has been entered USER CODES CODE 001 USER 001 STATUS 001 ENABLED Clear code Defa...

Страница 25: ...ED Activate Events item on user menu Default ENABLED A Activates code to accede to the Events item on the user menu EXTENS MENU 001 ENABLED Activate Extension item on user menu Default ENABLED A Activ...

Страница 26: ...WITCH ON OFF A SWITCH ON OFF The key is activated to switch on and off the areas associated to it ONLY TURN ON The key is authorised only to switch on the areas associated to it Example for assigning...

Страница 27: ...line Number to request the line from the pbx FORMAT 01 VOICE Telephone communication format Default see table at start VOICE The telephone communications will be of the voice type SMS The telephone c...

Страница 28: ...with area switching off properties NONE Events such as general technical or sabotage alarms and so on trigger a cycle of phone calls this CANNOT be interrupted once it has started by neither codes nor...

Страница 29: ...respond GSM RMT CTRL YES GSM SECURE YES ENABLE PHONES Activate control of PSTN line Default NO A If activated it checks control of the PSTN line if the line is down a breakdown notifications issued PS...

Страница 30: ...PREVIOUS STATUS Quick switch on Default DISARMED A If activated it lets you start scenarios from the keypads without having to enter a code Warning When activated prevents exclusion of open inputs dur...

Страница 31: ...g HH mm hour and minutes A action III address S status P extension To see the meaning of the values see the table below Example if programme step activates output 3 at 08 30 the following is displayed...

Страница 32: ...r time is done automatically according to the Italian national rule 03 46 01 01 10 YEAR 10 Set date F S A Use the arrow key to select the parameters to edit and with the keys edit the value Press to e...

Страница 33: ...eas man aged by the control unit the second de scription will read TOTAL whereas partial switching on will indicated the switched on areas example X PARTIALIS Areas switched on The partialisation even...

Страница 34: ...pansion module on the bus xx has been tampered with Check module tamper X TAMP MOD RX xx MODULE DESCR The tamper of the radio receiver of bus xx has been tampered with Check module tamper X TAMP TASTI...

Страница 35: ...xxx CODE DESCR Code xxx has been activated from the user menu The chronologically previous event CODE N xxx shows who has edited it WRONG CODE KEYPAD DESCR 21 wrong codes have been inserted from keyp...

Страница 36: ...ents Under Article 3 2 Of The R Tte Directive EN 301 489 3 Electromagnetic Compatibility And Radio Spectrum Matters Erm Electromagnetic Compatibility Emc Standard For Radio Equipment And Services Part...

Отзывы: