Resetting Thermostat

Non-Volatile Memory

The Reset feature allows the user to completely reset the thermostat and to register new 

manual 

˚F / ˚C

 temperature scale switch settings.

1.

 To erase all entered program settings, gently press 

RESET

 button using a paper clip or a  

small pencil tip.

2.

  This will return all thermostat settings to their default values and register all new manual

˚F / ˚C

 temperature scale switch settings.

In the event of a power failure, the Non-Volatile Memory feature of this unit allows all settings to 

be recovered, eliminating the need to reset temperature and differential settings. When AC 

power is restored after an outage, all settings are retrieved from memory and reinstated.

Thermostat does not 
turn on heating or 
cooling system.

Check to see if 

OFF

 is shown in display. This indicates that the 

system is turned off at the thermostat. Move the system selector 

switch to the 

HEAT

 or 

COOL

 position. After the compressor short 

cycle protection 5-minute period expires the system should start 

within a minutes time.
Compressor protection features may be in effect due to 

compressor short cycle conditions. See 

Compressor Protection

 

section for full explanation of this feature.

Check thermostat wiring to make sure that the heating and 

cooling stages are connected to the correct terminals on the 

wiring terminal block. See 

Installation 

and 

Wiring Diagram

 

sections of this manual.

Thermostat display 
is blank.

It is possible that AC power is not present at the thermostat. 

Check fuse, circuit breaker and thermostat wiring as appropriate 

to verify AC power is available. 
If AC Power is present, call a professional service technician 

immediately to verify thermostat and system performance.

SYMPTOM

POTENTIAL SOLUTION

Thermostat will not 
allow me to program 
a setpoint 
temperature higher 
than 90˚ F (32˚ C).

This is above the normal thermostat temperature setting range 

of 45˚ to 90˚ F (7˚ to 32˚ C).

Thermostat will not 
allow me to program 
a setpoint 
temperature lower 
than 45˚ F (7˚ C).

This is below the normal thermostat temperature setting range 

of 45˚ to 90˚ F (7˚ to 32˚ C). 

Fan continues to run 
all the time whether 
the system is on  
or off.

Check that the fan control switch is in the 

AUTO

 position. This 

will allow the fan to run only when the heating or cooling system 

is turned on and running.
Check thermostat wiring to make sure that the fan control 

wiring is connected to the correct terminals on the wiring 

terminal block. See 

Installation

 and 

Wiring Diagram

 sections of 

this manual.

LO

 is shown in the 

thermostat display 
where the room 
temperature is 
normally displayed.

HI

 is shown in the 

thermostat display 
where the room 
temperature is 
normally displayed.

The temperature sensed by the thermostat is higher than the 

90˚ F (32˚ C) upper limit of the thermostats display range. The 

display will return to normal after the sensed temperature 

lowers within the 45˚ to 90˚ F (7˚ to 32˚ C) display range. Turn on 

the cooling system or use other methods to lower the 

temperature accordingly.
This condition could occur from the system being turned off 

during an exceptionally warm period or upon installation when 

the thermostat has been stored for a long period of time in a 

warm vehicle or location prior to being installed. The thermostat 

is equipped with a mechanical high temperature safety switch 

that will turn off the thermostat should the temperature exceed 

99˚ F (37˚ C) in the heat mode.

TROUBLESHOOTING

6

cont.

SYMPTOM

POTENTIAL SOLUTION

TROUBLESHOOTING

6

Thermostat turns 
heating or cooling 
system on too often 
or not often enough.

Increase or decrease first stage temperature differential setting 

as appropriate to provide the desired performance level. See 

Setting Temperature Differential

 section of this manual.

Thermostat turns on 
second (auxiliary) 
stage of heating or 
cooling too quickly or 
not quickly enough.

Increase or decrease second (auxiliary) stage temperature 

differential setting as appropriate to provide the desired 

performance level. See 

Setting Temperature Differential

 section 

of this manual.

ADDITIONAL 

OPERATION FEATURES

5

5.4

cont.

5.5

Thermostat turns on 
heating instead of 
cooling, or cooling 
instead of heating.

The temperature sensed by the thermostat is lower than the     

45˚ F (7˚ C) lower limit of the thermostats display range.            

The display will return to normal after the sensed temperature 

rises within the 45˚ to 90˚ F (7˚ to 32˚ C) display range. If the 

temperature in the controlled space seems to be normal, wait for 

the thermostat to acclimate to the correct room temperature.       

If the room seems to be colder than usual, turn on the heating 

system to raise the temperature as needed for comfort within   

the room.
This condition could occur from the system being turned off 

during a cold weather period or upon installation when the 

thermostat has been stored for a long period of time in a cold 

vehicle or location prior to being installed. The thermostat should 

be allowed to warm up prior to installation to allow proper heating 

control once installed.