66-Block
display screen examples:
Display screen before text/zones
entered
Display screen showing 12-zone label
with the first of 12 zones displayed
110-Block Labels
Note:
See
DataComm & T-Block Menu Selections
for a list of the
high-level
DataComm
& T-Block Menu selections, their default values, and the corresponding softkeys.
This example outlines the functionality required to create a 110-Block label using the DataComm
& T-Block menu. 110-Block labels print based on user-selected pair configuration.
This example assumes use of a dedicated 110-Block part (width = .475").
To create a 110-Block label:
Step 1.
Insert a dedicated part (.475" x continuous in B412 and B422). The printer reads the
smart-cell settings and automatically displays the screen allowing you to choose between
the General ID Menu and DataComm & T-Block Menu. Upon selecting the DataComm
& T-Block Menu, the following datacomm menu options appear above the softkeys:
P-PNL, T-BLK, DESI, 110BLK, 66BLK, BIX.
Note:
To escape to the
General ID Menu
screen press
FUNCTION
+
CLEAR/ESC
.
Step 2.
Press
NEXT
, then the
110-BLK
softkey. The default
110-block
information automatically
appears on the display screen as shown below (pressing
NEXT
advances menu options):
Step 3.
To set or accept the pair configuration (
2PR
,
3PR
,
4PR
, or
5PR
), do one of the following:
•
Press the
ENTER
key to accept the default (
4PR
), or
•
Press another pair configuration softkey and press
ENTER
.
Note:
For instruction on using the BLANK selection, see
Blank Pair Type
on page
30
.
Note:
See also
Horizontal Serialization
on page
31
and
Backbone Serialization
on
page
32.
User Manual
27