Assembly of Components

Parts List

 

S24-188 

Plastic Showerhead Assembly

  1.1 

S24-187 

Flow Control Assembly, 23 GPM

 

S19-0011 

Self-Closing Spring Assembly

  2.1 

S27-286 

Ball Valve with Jam Nut

  2.11 

110-214 

Jam Nut only

 2.2 

142-002CH 

Washer

 2.3 

128-129 

Handle

 2.4 

140-720 

Stop 

Bracket

  2.5 

S19-001 

Kit, Spring Torsion

 

113-006LN 

Pipe Nipple 1" Close

 

169-860A 

1/4" Nylon Cord

 5 

269-646 

1  “S” 

Hook

 6 

269-655 

1  Pulley

 7 

269-765 

1  Eye 

Screw

 8 

114-050 

1  Safety 

Sign

 

204-421 

Emergency Inspection Tag

  10 

169-1027 

Coupling 1" NPT

 

Item Part 

No. 

Qty Description

Item Part 

No. 

Qty Description

2.5

2.4

2.3

2.2

2.11

5

2.1

3

1.1

7

4

6

P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA

TEL: 1-800-BRADLEY    FAX: (262-251-5817)

http://www.bradleycorp.com

114-050

8

P.O. Box 309, Menomonee Falls, WI 53051

R

TEST THIS  UNIT  EACH WEEK

Test-operate valve(s) each week and sign below.
Report any malfunctions immediately.

Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt 
durch Unterschrift. Jegliche Störung sofort melden. 

Date
Datum
Date

Signed
Unterschrift
Signe

Date
Date

Date

Signed
Signed
Signed

DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN.
ESSAI HEBDOMADAIRE

Test le fonctionnement des valves chaque semaine et 
signe en bas. S'il y à quelque chose qui ne va pas fait  
un rapport immédiatement. 

9

1

2

10

1" NPT 

Supply Inlet

NOTE: Use 

teflon tape 

only.

Содержание S19-130F

Страница 1: ...00 272 3539 FAX 262 251 5817 bradleycorp com Installation 215 152CO Rev P ECN 08 512 2008 Bradley Corporation Page 1 of 4 9 11 08 S19 130F Drench Shower Cord Operated Table of Contents Pre Installation Information 2 Installation 3 S19 130F Components and Parts List 4 ...

Страница 2: ...operation This equipment should be inspected annually to ensure compliance with ANSI Z358 1 Workers who may come in contact with potentially hazardous materials should be trained regarding the placement and proper operation of emergency equipment per ANSI Z358 1 For questions regarding the operation or installation of this product visit www bradleycorp com or call 1 800 BRADLEY Product warranties ...

Страница 3: ... floor Step 2 Connect water supply IMPORTANT Do not rely on Bradley s Drench Shower to support supply piping 1 Connect water supply piping to 1 NPT inlet on unit piping supplied by installer Provide adequate supports supplied by installer for supply pipe using pipe hangers or other means 2 Mount the pulley and the eye screw to the wall pulley hardware supplied by installer 3 Secure one end of the ...

Страница 4: ...7 1 Coupling 1 NPT Item Part No Qty Description Item Part No Qty Description 2 5 2 4 2 3 2 2 2 11 5 2 1 3 1 1 7 4 6 P O BOX 309 MENOMONEE FALLS WI 53052 0309 USA TEL 1 800 BRADLEY FAX 262 251 5817 http www bradleycorp com 114 050 8 P O Box 309 Menomonee Falls WI 53051 R TEST THIS UNIT EACH WEEK Test operate valve s each week and sign below Report any malfunctions immediately Ventil e wöchentlich i...

Отзывы: