background image

COBALT Pro

 Exposed Flush Valve  

Standard Operations

101819 / 101673

I-CON  Systems,  Inc.,  for  product  support  call  1-866-730-7192  or  visit  us  online  at  support.i-con.com                           

One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents

  USER MODE

page 1

Rev 081723

The normal state of the valve. The valve is in user mode when it detects that its cover is on, or if it has been in maintenance  

mode for more than 30 minutes. Auto Activations are only available in user mode.

ACTIVATION

Auto-Activation

The valve will automatically flush based on IR detection. The IR sensor has 3 LEDs, a red, green, and blue to indicate detection 

 

and activation status.

When no object is detected no LED indication will display. After 5-7 seconds of detecting an object, the valve will be considered 

“locked on” and a green LED will blink in 5-second intervals up to 30 seconds.

When an object exits from lock-on the valve will Auto-Activate.

Manual Activation

There are two manual activation buttons atop the valve. The left button performs a reduced flush, while the right button 

 

performs a standard flush.

Sentinel Activation

The valve can automatically activate 24 hours after the last activation, by default Sentinel Activation is off. To toggle Sentinel 

Activation on and off hold down the Activate button on the control module (not the Manual Activation buttons) for 5 seconds. 

 

The green LED will blink 3 times to indicate it has been turned on, or the red LED will blink 3 times to indicate it has been turned off.

Activation Refusal

When an activation is attempted but the valve is unable to activate, a red LED will flash. This can be caused by end-of-life battery, 

obstructions, being temporarily disabled. Valves are automatically temporarily disabled for 3 seconds after an activation.

TruFLUSH®

Pro devices use TruFLUSH®, an algorithm based on water pressure to optimize flush volumes.

  DEFAULT SETTINGS

Urinal

Water Closet

Range

22”

40”

Exit Time

1 second

3 seconds

Water Savings

0%

0%

Base Volume

0.25gpf

1.1gpf

Redetect Time

1 second

15 seconds

Reviews: