background image

TSL.R.020

Sensor Faucet

in

st

al

la

tion + m

ain

ten

an

ce

Summary of Contents for TSL.R.020 Series

Page 1: ...TSL R 020 Sensor Faucet installation maintenance ...

Page 2: ...a 7 Before You Install 8 How to Install 11 The Complete System 12 Resetting the Sensor 14 Maintenance 14 Cleaning 15 Spare Parts 15 Product Identification 16 Troubleshooting 17 Warranty 18 Contact Details contents 2 TSL R 020 RIBBON SENSOR FAUCET MANUAL ...

Page 3: ...ical isolation must be incorporated in the fixed wiring in accordance with the current local regulations in force Disconnect the power supply before performing any maintenance on the product Children should not play with this equipment Cleaning and maintenance shall not be performed by children without supervision This equipment is designed to be used in commercial and public areas it is not inten...

Page 4: ...UCET MANUAL box contents A B C D E F G I H A Ribbon sensor faucet head B Mains power supply C Battery supply D Anti rotation plate 1 E Counter top gasket F Anti rotation plate 2 G Fixing nut H Solenoid and cable I Flow restrictor ...

Page 5: ...rushed Bronze Material body AISI304 Stainless steel Operating pressure 7 5 145psi dynamic pressure Flow rate 0 5GPM Other flow rates available on request Water supply Premixed through thermostatic mixing valve supplied by others Weight 2lb 3oz Power supply Mains Input 100 240V 50 60Hz 1 5A Output 6V DC 1A 6W max Low voltage connector two pin waterproof plug Power supply Battery 6V Type CR P2 lithi...

Page 6: ...T MANUAL technical data FRONT SIDE 4 31 32 7 5 16 5 21 32 4 17 32 3 19 32 Ø 1 1 4 3 8 MIN 1 3 8 MAX 2 23 32 2 1 8 1 2 BSP MAX Length 11 13 16 Battery Power Supply 6 Default Sensor Range 4 3 4 Ø 1 11 32 Through Hole Mains Power Supply ...

Page 7: ...older cover and replace the battery ensuring the correct polarity Affix the cover and tighten the screws making sure the cable is fed through the purpose made grooves in the holder Flow Rates Different flow rates may need to be achieved The Splash Lab offer a number of flow regulators which can be used in conjunction with the Ribbon Tap system see installation guide or contact The Splash Lab for m...

Page 8: ...on sensor tap head A These should be shipped preinstalled Ensure that the mains water supply has been deactivated at or before point of install prior to fitting 2 Position tap on sink deck through a Ø 1 1 4 hole and ensure the tap is angled pointing in the required direction Remove reflective clothing during installation how to install ...

Page 9: ... fixings are required at this stage Alternative solid surface Sink b When using another solid surface sink micro squirrel fixings will need to be fitted prior to install The under sink anti rotation plate F can be secured in place with 2x M4 M5 fixings The Splash Lab Approved Sink c Other scenarios will require a soffit of timber or MDF I to be fitted under the sink The under sink anti rotation pl...

Page 10: ...f the flexi hose onto the outlet of the solenoid ensuring that the flow restrictor is in place between the fixing nut and the solenoid valve 6 Connect the solenoid inlet to the mains water supply using a flexi hose only not supplied 7 Before powering on the system remove the label covering the sensor at the front of the tap left 8 Attach the female sensor cable from the main unit to either the bat...

Page 11: ...he complete system Water Aerator Mains Water Supply Flexi Hose 110 240 Volt Mains Supply A B C H I A B C H I A B C H I A B C H I A B C H I A Ribbon sensor faucet head B Mains power supply C Battery supply H Solenoid and cable I Flow restrictor ...

Page 12: ...he Ribbon Tap head from the Power unit Wait a minimum of 4 seconds and reconnect the power 2 Look under the tap at the sensor near the nozzle You should see a flashing red light When you see the light position your hand within 2 of the tap If you do not see the light repeat from step 1 ...

Page 13: ...t stops flashing move your hand down to the desired activation position and hold 4 When the light goes out the new detection distance is set Test the system and repeat from step 1 until the tap works as required Remove reflective clothing during installation ...

Page 14: ...dic abrasive or cream cleaners as these will damage the surface finish maintenance Some of the components in the Ribbon system are liable to fail over time and may need maintenance and replacing The Ribbon system has been developed to accommodate for this maintenance yet all work should be done by a trained member of an approved maintenance team For more information contact The Splash Lab ...

Page 15: ... components are under warranty and the parts have become non functioning during normal use within their assumed usable life they may be replaced Should a replacement mains power supply be required it is imperative that an identical type is used Contact The Splash Lab for further information product identification A unique product identification code can be found on the product tag attached to the ...

Page 16: ...ating and supplying 6 volts Replace battery on battery powered versions Sensor range is incorrect Adjust sensor settings see page 10 and 11 or contact The Splash Lab to purchase remote controller Water does not flow Valve can be heard to open Water supply is blocked to valve Check and clean filter on solenoid valve Check water supply for any blockages or restrictions Water pressure is too low Chec...

Page 17: ...ars parts labour If a defect is found in normal use The Splash Lab will at their discretion repair provide a replacement part or product or make appropriate adjustments Damage caused by accident misuse or abuse is not covered by this warranty Improper care and cleaning will void the warranty Non operation of the product due to environmental conditions beyond our control installation error incorrec...

Page 18: ...R FAUCET MANUAL contact General information 1 310 410 5008 5450 W 83rd St Los Angeles CA90045 500 7th Ave New York NY10018 Technical support technical thesplashlab com For further contact information visit www thesplashlab com ...

Page 19: ...TSL R 020 RIBBON SENSOR FAUCET MANUAL 19 ...

Page 20: ...TSL R 020 US REV 1 04 04 18 ...

Reviews: