background image

P.O. Box 309, Menomonee Falls, WI  USA  53052-0309
PHONE 800.BRADLEY (800.272.3539)  FAX 262.251.5817

bradleycorp.com

Installation 

215-1736 Rev. B EN 12-03-009
© 2012 Bradley
Page 1 of 4 

8/7/2012

S59-1000T1

Bradley Equa-Flo

 EFT1  

Pressure-Balancing Shower Valve

Table of Contents

LCD Display Information ...................................................2
Rough-in/Dimensional Information ...................................2
Installation Instructions .....................................................2
Connecting Valve and Adjusting Temperature ..................3
Attach Escutcheon and Handle ........................................4

IMPORTANT!

Read this entire installation manual to ensure proper installation. When finished 
with the installation, file this manual with the owner or maintenance department. 
Compliance and conformity to local codes and ordinances is the responsibility of 
the installer.

Hot limit screw is set in the maximum temperature position. Failure to adjust 
properly may result in serious scalding. This valve may not protect from scalding 
if there is a failure of other temperature-controlling devices elsewhere in the 
plumbing system. Excessive heat may cause damage to internal parts.

Separate parts from packaging and make sure all parts are accounted for before 
discarding packaging material. If any parts are missing, do not begin installation 
until you obtain the missing parts.

Make sure that all water supply lines have been flushed and then completely 
turned off before beginning installation. Debris in supply lines can cause valves 
to malfunction.

Product warranties may be found under “Products” on our web site at  
www.bradleycorp.com.

Installation

THIS
SIDE

UP

Packing List

Supplies Required

•฀

Teflon Tape

•฀

Allen Key Wrenches

•฀

Screwdriver

•฀

1/2" NPT Brass Pipe Plug

•฀

Adjustable Wrench

ASSE 1016 & UPC Certified

For use with shower heads rated 
at 5.7 L/min (1.5 gpm) or higher.

Содержание Equa-Flo EFT1

Страница 1: ...rature position Failure to adjust properly may result in serious scalding This valve may not protect from scalding if there is a failure of other temperature controlling devices elsewhere in the plumbing system Excessive heat may cause damage to internal parts Separate parts from packaging and make sure all parts are accounted for before discarding packaging material If any parts are missing do no...

Страница 2: ...F 21 C If the water temperature is below 70 F 21 C the display will refresh every 10 seconds 3 The unit can be configured to display F or C by a slide switch inside the display s battery compartment see Step 2 4 A Low Battery indicator will turn on when batteries have approximately one month of power remaining AAA alkaline batteries supplied 8 203 72 1829 40 1016 Temperature Probe Tee on Bottom of...

Страница 3: ...rk on Cap Arrow on Cap Hot Limit Stop Off Stop Set Screw You can fine tune the hot limit stop position 1 2 spline by flipping it over Limit Stop Normal Limit Stop Flipped FOR BACK TO BACK INSTALLATIONS A Turn off water supplies and remove 2 hold down screws from the reversed valve Rotate cap and cartridge assembly 180 and re install screws B Remove both limit stops and rotate 180 Align with alignm...

Страница 4: ...ation 4 8 7 2012 Bradley 215 1736 Rev B EN 12 03 009 A Place the escutcheon on the wall over the valve and secure with the screws provided B Place handle on stem as shown and tighten screw Attach Escutcheon and Handle 3 ...

Отзывы: