S59-1000T1
Installation
2
8/7/2012
Bradley
•215-1736Rev.B;EN12-03-009
Shower Only Installation
5"
(127)
6-1/2" (165)
w/ Stops
2-1/2" (64)
w/o Stops
Hot
Cold
Front View
(mm)
Dimensional Information
LCD Display Information
The Bradley Equa-Flo
™
EFT1 S59-1000T1 LCD Shower Valve is designed to operate for up to 2 years on a set of high-quality
alkaline batteries*. Bradley strongly recommends using only high-quality, name-brand alkaline batteries for maximum performance.
When operating at normal room temperatures, the LCD display will convey accurate water temperatures between 40°F –120°F
(4°C–49°C). For safety and comfort, a number of special features are built into the display:
1. Display will flash "HHH" when water temperature exceeds maximum operating limit of 120°F (49°C). It will display "LLL"
when water temperature falls below minimum operating limit of 40°F (4°C).
2. Display will refresh every 2 seconds when the water temperature reaches 70
°
F (21
°
C). If the water temperature is below
70
°
F (21
°
C), the display will refresh every 10 seconds.
3. The unit can be configured to display °F or °C by a slide switch inside the display's battery compartment (see Step 2).
4. A
"Low Battery"
indicator will turn on when batteries have approximately one month of power remaining.
* AAA alkaline batteries, supplied.
8"
(203)
72"
(1829)
40"
(1016)
Temperature
Probe Tee on
Bottom of Valve
1/2"
NPT
1/2"
NPT
1/2" NPT Plug
(not supplied)
3-1/2" (89) Max.
3-1/4" (83) Min.
3-7/8" (98) Max. Depth
3-5/8" (92) Min. Depth
Tub/Shower Installation
12"
(305)
Use rough-in
hole template
(215-1735) for
finished wall
(provided).
3-5/8"
(92)
3-1/4"
(83)
3/4"
(19)
2-3/4"
(70)
6-3/4"
(175)
R: 2-3/4"
(70)
Valve
Center
1-7/8"
(48)
4-1/2"
(114)
1-1/4"
(32)
Floor
8"
(203)
24"
(610)
72"
(1829)
48"
(1219)
Temperature
Probe Tee on
Top of Valve
1/2"
NPT
1-1/2"
(38)
3-1/4" (83) Max.
2-1/2" (64) Min.
3-7/8" (98)
Max. Depth
3-1/8" (79)
Min. Depth
1/2" NPT Plug
(not supplied)
Floor
•
Rough-in 1/2" NPT hot and cold water
supply (supplied by installer).
•
For finished wall, rough-in hole using
template (215-1735) provided.
"Back-to-Back" Installation
Hot
Cold
Standard
Install
Supplies
Reversed
Installation Instructions
Rough-in
1