Installation
S93-572, S93-573, S93-574
Bottom View -
Infrared
5.3 Electrical Connections - Infrared
A
Install a GFI receptacle (supplied by
installer) at location shown on rough-in
drawing .
B
Plug the power connection of the power
adapter (261-147A) into the power jack
receptacle of the 2 station harness
(S83-367B)
C
Turn on the water supply to test the unit
and check for leaks .
D
Turn on the electrical power and pass
your hand in front of each sensor to
verify activation .
Power Adapter
(261-147A)
Left Sensor
Right Sensor
Left Green
Tubing
Right Red
Tubing
Nut 5/16-18
(161-036)
Washer
(142-088)
Solenoid Ganged Valve
Assy . (S45-3485)
Washer (142-002BS)
Nut 1/4-20
(161-026)
Connect to
Right Station
Connect to
Left Station
Power Jack from Harness
(S83-367B)
WARNING The infrared control must be connected with a 12V DC plug in adapter. Connections to
110 VAC can cause personal injury and will result in damage to the electronics.
CAUTION Connections of leads other than shown may cause permanent damage to the sensor.