10
9/28/2017
Bradley •
215-1595 Rev. E; ECN 17-00-014
S93-572, S93-573, S93-574
Installation
Bottom View - TouchTime
5.2 Electrical Connection - TouchTime
A
Install a GFI receptacle (supplied by
installer) at location shown on rough-in
drawing .
B
Plug the power connection of the power
adapter (261-147A) into the power jack
receptacle of the TouchTime module
(S83-360) .
C
Turn on the water supply to test the unit
and check for leaks .
D
Turn on the electrical power and
depress each push button to verify
activation .
Navigator
Mixing Valve
Green
Tubing
Left
Button
Right
Button
TouchTime Switch
(S83-368)
Washer
(142-088)
Nut 5/16-18
(161-036)
Nut 1/4-20
(161-026)
Washer
(142-002BS)
Solenoid Ganged Valve
Assy . (S08-2402TMA)
Red
Tubing
Compression Nuts
Green
Supply Tube
Red Supply
Tube
TouchTime Module
(S83-360)
Each female jack plugs into the male
jack port of the TouchTime module
(S83-360)
2-Way Splitter
(251-027A)
Plug-In Adapter
(261-147A)
WARNING The TouchTime control must be connected with a 12V DC plug in adapter. Connections
to 110 VAC can cause personal injury and will result in damage to the electronics.
CAUTION Connections of leads other than shown may cause permanent damage to the sensor.